Pro-Cut X9 Technical Manual page 44

Table of Contents

Advertisement

USING THE 50-1250 CUTTING HEAD
If a rotor has an extra wide face width, or if the inboard face is wider than the outboard face, the
inserts may be adjusted to allow for staggered cheeks by loosening the throat depth lock screws,
moving the insert holder to the desired position and then re-tightening the throat depth lock screws.
50-1250 CUTTING HEAD
TO FIT THE TOOL HOLDER PLATE TO THE SLIDE PLATE:
Loosen the travel limit screw until it no longer crosses
1.
the slot on the bottom surface of the tool holder plate.
2.
Carefully loosen the position lock lever until the cam on
the bottom surface is just below flush with the bottom
surface of the tool holder plate.
3.
Slide the cutting head over the male dovetail on the
slide plate.
Once in place re-tighten the position lock lever (4) and
4.
the travel limit screw (1).
PG /
800.543.6618
44
CONTINUED
ASSEMBLY
1
2
4
3

Advertisement