2.7.2 Alarm Output Connection
Follow the figure bellow to wire alarm output.
n and n# are a pair of alarm output. You can connect them with a relay alarm device. When
the voltage of connected alarm device exceeds the valid alarm output range, you need to
connect a relay to protect alarm output.
n
Relay
Output
n#
Alarm Powered by Direct Current
2.8 Sensor-in Wiring
Step 1 Connect the delivered extension cable to I/O interface.
Step 2 Connect the automobile braking, reversing, left-turn, and right-turn signals to sensor-in
interface.
2.9 Power-on
Turn on the power supply after all the above installations are finished.
Mobile Network Video Recorder User Manual
Load
Relay
Output
Figure 2-21 Alarm Output Connection
Left-turn Right-turn
2
1
Figure 2-22 Sensor-in Wiring
GND Power
Output
n#
n
Alarm Powered by Alternating Current
Reversing
IO
Braking
22
JQC-3FG
Relay
(10 A/250 VAC)
~ 220 VAC
Live
Neutral
16