Grounding Generator To Truck Or Trailer Frame; Installing Exhaust Pipe - Miller Trailblazer 325 Diesel Owner's Manual

Diesel engine driven welder
Hide thumbs Also See for Trailblazer 325 Diesel:
Table of Contents

Advertisement

5-2. Grounding Generator To Truck Or Trailer Frame

!
Always ground generator frame to
vehicle frame to prevent electric
shock and static electricity hazards.
!
Also see AWS Safety & Health Fact
Sheet No. 29, Grounding of Portable
And Vehicle Mounted Welding Gen-
erators.
!
Bed liners, shipping skids, and
some running gear insulate the
welder/generator from the vehicle

5-3. Installing Exhaust Pipe

Tools Needed:
9/16 in. Or 14 mm
OM-258900 Page 22
.
Complete Parts List available at www.MillerWelds.com
GND/PE
frame. Always connect a ground
wire from the generator equipment
grounding terminal to bare metal on
the vehicle frame as shown.
!
Use GFCI protection when operat-
ing auxiliary equipment. If unit does
not have GFCI receptacles, use
GFCI-protected extension cord. Do
not use GFCI receptacles to power
life support equipment.
1
1
2
3
1
2
3
Connect cable from equipment ground
terminal to metal vehicle frame. Use #8
AWG or larger insulated copper wire.
.
2
rot_grnd2 2012−03 − 800 652-D
Equipment Grounding Terminal (On
Front Panel)
Grounding Cable (Not Supplied)
Metal Vehicle Frame
Electrically bond generator frame to
vehicle frame by metal-to-metal con-
tact.
!
Stop engine and let cool.
!
Do not blow exhaust toward
right side of unit where air inlet
is or air cleaner may need to be
replaced more often. Point ex-
haust pipe in desired direction
but always away from front
panel and direction of travel.
1
Exhaust Pipe
2
Exhaust Pipe Clamp
Slide clamp over muffler pipe. Slide
exhaust pipe onto muffler pipe and ro-
tate exhaust pipe to desired position.
Secure exhaust pipe with clamp.
259 703