Operating Controls - B&D EconoLift Installation Instructions Manual

Automatic rolling garage door opener
Table of Contents

Advertisement

1.
P. E. SHUNT. The shunt has to be
removed when connecting a Photo
Electric Beam.
NOTE: P.E. SHUNT must not be
removed otherwise the opener will
not function correctly. Remove
only when a P.E beam is to be
connected.
2.
STATUS LED (Yellow) indicates
when the datum adjustment screw
has reached correct position.
3.
DATUM ADJUST SCREW
Used to set mid point of door trav-
el during limits set up.
4.
DOOR CODE button (blue) is
used for storing or erasing the
transmitter button you wish to use
to command the door to open, stop
or close.
5.
CODING
LED
indicates whether a code is being
stored or when a transmitter button
is pressed.
6.
SET button (orange) is used
during the installation phase
together with the Plus and Minus
buttons to set the door limit
positions. The Set button is also
used to re-initialise the Opener.
©Copyright 2006 B&D Doors

OPERATING CONTROLS

7.
OPERATE button (blue) is used
during installation to test the open,
stop and close cycles for the
opener. The opener has to be
initialised by the Set button before
the OPERATE button becomes
operable.
8.
FORCE MARGIN SET The
obstruction force pressure is set
automatically by the opener during
installation. The pressure can be
adjusted manually using the Force
Margin
Pressing the force margin set
button and open or close button
will increase or decrease the
amount of force. The Force Margin
Set is only ever used if other
environmental factors (wind, etc.)
affect the operations of the
door/opener.
9.
PLUS button (green) can be used
(red)
light
during installation to set the open
limit position. Pressing this button
will move the door in the open
direction. Movement stops when
the button is released.
NOTE:
obstruction
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.
This button is also used to increase
the force margin sensitivity.
Set
button
(White).
The
open
safety
detection
is
5
10.
OPEN LIMIT LED (green) the
led
is
very
helpful
installation. It illuminates and
flashes when the door is opening
and remains steady on when the
open limit position has been
reached.
11.
MINUS button (red) can be used
during installation to set the close
limit position. Pressing this button
will move the door in the close
direction. Movement stops when
the button is released.
NOTE:
The
close
obstruction
detection
inoperable whenever the Close
Drive button is used to move
door. This button is disabled
after initialisation.
This button is also used to decrease
the force margin sensitivity.
12.
CLOSE LIMIT LED (red) the led
is very helpful during installation.
It illuminates and flashes when the
door is closing and remains steady
on when the close limit position
has been reached.
13.
ENGAGE/DISENGAGEMENT
CORD is used to switch the door
into manual mode especially in
case of a power failure. The length
of the string is also adjustable.
during
safety
is

Hide quick links: