DEFAULT SETTINGS AND SPECIFICATIONS
MAXIMUM MOTOR RUN TIME
OBSTRUCTION FORCE MARGIN
INPUT VOLTAGE:
CONTROLLER VOLTAGE:
STANDBY POWER:
MOTOR POWER:
MOTOR TYPE:
OPERATING TEMPERATURE:
MAXIMUM DOOR OPENING:
RATED LOAD:
RECOMMENDED LOAD:
OPENER LIMITS TRAVEL:
OPERATING TIME - INTERMITTENT:
RECEIVER TYPE:
RECEIVER CODE STORAGE CAPACITY:
TRANSMITTER FREQUENCY:
CODING TYPE:
No. of CODE COMBINATIONS:
TRANSMITTER BATTERY:
Note:
1. The maximum continuos curtain residential roll up door opening that the EconoLift can be installed on is 5500mm wide by
2700mm high. The door must be well balanced. A person of average strength should be able to lift up the door manually with very
little effort in case of an emergency.
2. Intermittent operations may occur in areas which experience very strong winds. The strong wind puts extra pressure on the door
and tracks which may in turn trigger the safety obstruction detection system intermittently.
©Copyright 2006 B&D Doors

FACTORY DEFAULT SETTINGS

TECHNICAL SPECIFICATIONS

1,2
WIDTH:
HEIGHT:
WEIGHT:
DEFAULT
30 Secs.
8
230V - 240V AC 50Hz
24V DC
2.8 Watts
100 Watts
24V DC Permanent Magnet
+5° to +40°C
5500mm
2700mm
100Kg
450N (45Kg)
200N (20Kg)
3.0 Turns of Door Drum Wheel
4 Minutes
UHF 433.92 MHz. AM Receiver
6 Smart Code Transmitters
1 Dipswitch Transmitter
1 Entry Keypad
433.92 MHz
Fixed
Over 3.86 Billion Codes
2 x 3V Type 2032 Button Cell
16