10.4" Lectern/Wall Mount Touchpanel
The easiest method of
programming, but does not
offer as much flexibility as
SIMPL Windows.
22 • 10.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys® TPS-4000L
The following are the minimum required software versions for the PC:
(Optional) SystemBuilder version 2.0 (due in fourth quarter of 2004) or
later with SystemBuilder Templates version 1.0.1or later. Requires SIMPL
Windows.
(Optional) D3 Pro version 1.2.7 or later. Requires SIMPL Windows.
SIMPL Windows version 2.05.22 or later with Library Update 302 or later.
Requires SIMPL+ Cross Compiler version 1.1.
Crestron Database version 16.3.4 or later. Required by SIMPL Windows,
VT Pro-e, and Crestron Engraver.
Crestron VisionTools Pro-e version 3.2.18 or later. Used for graphical
touchscreen design.
Crestron Engraver 2.2.1.2 or later.
The latest versions can be obtained from the Downloads | Software Updates section
of the Crestron website (www.crestron.com). Crestron software and any files on the
website are for Authorized Crestron dealers and Crestron Authorized Independent
Programmers (CAIP) only. New users may be required to register to obtain access to
certain areas of the site (including the FTP site).
NOTE: The TPS-4000L touchpanel is supplied with five blank pushbuttons.
Optional custom engraved keys can be ordered separately by using the Crestron
Engraver Software. Version 2.2.1.2 or later is available from the Downloads |
Software Updates section of the Crestron website (www.crestron.com).
Digital, analog and serial join numbers are a common thread between VT Pro-e and
SIMPL Windows. These numbers define how the objects on a touchpanel page of a
VT Pro-e project interface to the outside world, specifically the Cresnet system as
defined in the SIMPL Windows program. There are digital join numbers that carry
out some predetermined function (a logical high or low); analog join numbers for
displaying incremental values, sliders, gauges and bar graphs; and serial join
numbers that allow for the display of variable text and transmission/reception of
serial commands from other manufacturers. Unjoined objects are not interfaced with
the system and thus cannot initiate any logic functions (although they can perform
page flips).

Programming with the Crestron SystemBuilder

Crestron SystemBuilder offers automatic programming for such residential and
commercial applications as audio distribution, home theater, video conferencing, and
lighting. The interface of this tool guides you through a few basic steps for
designating rooms and specifying the control system, touchpanels, devices, and
functionality. Crestron SystemBuilder then programs the system, including
touchpanel projects and control system logic.
Crestron SystemBuilder is fully integrated with Crestron's suite of software
development tools, including SIMPL Windows, VT Pro-e, and the Crestron
Database. Crestron SystemBuilder accesses these tools behind the scenes, enabling
you to easily create robust systems.
®
Crestron Isys
TPS-4000L
Operations Guide – DOC. 6301