10.4" Lectern/Wall Mount Touchpanel
RS-232 SETTINGS
TIMEOUT SETTINGS
DIAGNOSTICS MENU
14 • 10.4 Inch Lectern/Wall Mount Touchpanel: Crestron Isys® TPS-4000L
RS-232 Menu
The touchpanel allows for three RS-232 communication methods: console (i.e.
loading programs), touch output (communication of touch coordinates to an external
device) or external touch screen input. Refer to "Appendix: Configuring the RS-232
Port for Use" on page 43 for more information.
For convenience, the RS-232 Menu also permits the selection of the RS-232
communication options, RTS-CTS On or Off, XON-XOFF On or Off, Baud Rate,
Data Bits, Parity, and Stop Bits.
Touch the communication option to select communication parameters and then select
Save and Return to save the RS-232 settings and return to the SETUP MENU.
Default settings are: 115200 baud, 8 bit, parity none, stop bit 1, XON/XOFF off,
RTS/CTS off.
Timeout Settings
The touchpanel display can be automatically turned off (standby mode) when not in
active use. Select the Timeout button on the SETUP MENU to reveal the
TIMEOUT SETTINGS display, shown to the left. This setting automatically turns
the display off when the touchpanel is inactive for a specified time. Touch the screen
to awaken the touchpanel and the last screen to be displayed reappears. The time
value, represented by 90 in the illustration, can range from 0 (disables the timeout) to
120 (minutes). Two buttons, UP and DOWN, increase and decrease the timeout,
respectively. Select the Return button to save the timeout setting and return to the
SETUP MENU.
Diagnostics Menu
The Diagnostics button from the MAIN MENU should only be used under
supervision from a Crestron customer service representative during telephone
support. The options available from the DIAGNOSTICS MENU, shown to the left,
are numeric in nature and their interpretation is beyond the scope of this manual.
NOTE: The "About..." button will display a screen indicating the current version
of firmware residing on the touchpanel.

Hardware Hookup

The TPS-4000L can be mounted in a wall or inside a lectern. Make the necessary
connections as called out in the illustration that follows this paragraph. For network
wiring information, refer to "Network Wiring" on page 7 before attaching the
4-position mini-terminal block connector. Apply power after all connections have
been made.
CAUTION: Do not apply excessive pressure to the touchscreen display during
handling (mounting/installation). Doing so can crack the screen and damage the
touchpanel.
®