Mounting Positions Of Local Controls; Mounting Positions: Modify - AUMA SAEx 07.2 Manual

Hide thumbs Also See for SAEx 07.2:
Table of Contents

Advertisement

SAEx 07.2
SAEx 16.2/SAREx 07.2
ACExC 01.2 Non-Intrusive HART
5.5.

Mounting positions of local controls

5.5.1.

Mounting positions: modify

SAREx 16.2 Control unit: electronic (MWG)
Figure 21: Mounting positions
The mounting position of the local controls is implemented according to the order.
If, after mounting the actuator to the valve or the gearbox on site, the local controls
are in an unfavourable position, the mounting position can be changed at a later
date. Four mounting positions shifted by respectively 90° are possible (by maximum
180° into one direction).
Ignition of potentially explosive atmospheres caused by sparks.
Risk of death or serious injury.
Before opening the flameproof enclosure, ensure absence of gas and voltage.
Handle cover and housing parts with care.
Joint surfaces must not be damaged or soiled in any way.
Do not jam cover during fitting.
Electrostatic discharge ESD!
Risk of damage to electronic components.
Earth both operators and devices.
1.
Loosen screws and remove the local controls.
2.
Check whether O-ring is in good condition, correctly insert O-ring.
3.
Turn local controls into new position and re-place.
Cable damage due to twisting or pinching!
Risk of functional failures.
Turn local controls by a maximum of 180°.
Carefully assemble local controls to avoid pinching the cables.
4.
Fasten screws evenly crosswise.
Assembly
25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents