Assembly; Mounting Position; Handwheel Fitting; Mount Actuator To Valve - AUMA SAEx 07.2 Manual

Hide thumbs Also See for SAEx 07.2:
Table of Contents

Advertisement

SAEx 07.2
SAEx 16.2/SAREx 07.2
ACExC 01.2 Non-Intrusive HART
5.

Assembly

5.1.

Mounting position

5.2.

Handwheel fitting

How to proceed
5.3.

Mount actuator to valve

SAREx 16.2 Control unit: electronic (MWG)
When using grease as lubricant, the product described herein can be operated in
any mounting position.
When using oil instead of grease within the actuator gear housing, perpendicular
mounting position is specified whereby the flange is pointing downward. The type of
lubricant used is indicated on the actuator name plate (short designation F...= grease;
O...= oil).
To avoid transport damage, handwheels are supplied separately as appropriate. In
this instance, the handwheel must be mounted prior to commissioning.
Figure 10: Handwheel
[1]
Spacer
[2]
Input shaft
[3]
Handwheel
[4]
Retaining ring
1.
If required, fit spacer [1] on input shaft [2].
2.
Slip handwheel [3] onto input shaft.
3.
Secure handwheel [3] with retaining ring [4].
Information: The retaining ring [4] (together with these operation instructions)
is stored in a weatherproof bag, which is attached to the device prior to delivery.
Corrosion due to damage to paint finish and condensation!
Touch up damage to paint finish after work on the device.
After mounting, connect the device immediately to electrical mains to ensure
that heater minimises condensation.
Assembly
17

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents