6.11.17 Ethernet settings

The ethernet interface can be used for remote monitoring with the DEGA VISIO visualization tool, to alert the user in the event
of an alarm using classic email messages or to connect the control panel to a remote PLC using the Modbus protocol.
Dialog item
IP address
Netmask
Default gateway
DNS
Use DHCP
DEGA VISIO
E-mail
Modbus RTU
Cloud
Table 32 Ethernet settings
Tip: The ethernet interface is set to 100 mbit/s, full duplex. The autonegotiation function is not used.
Figure 57 Ethernet settings
Description
Static configuration settings - IP address
Static configuration settings - network mask
Static configuration settings - default gateway
Static configuration settings - DNS server
Enables dynamic configuration of the IP protocol using DHCP
Client enable / settings for DEGA VISIO server (visualization SW)
Enable / configure mail client for sending notifications
Enable / set Modbus TCP protocol
Enable / configure the client to send process data to the data
store
67
User
Service