ESAB A6 TFD1 Operating Manual page 11

Hide thumbs Also See for A6 TFD1:
Table of Contents

Advertisement

Available languages

Available languages

Filling with flux (applies to A6 TFD1 och A6 TFD2)
1. Close the flux valve on the flux container.
2. Remove the separator from the flux recovery unit, if fitted. Fill with flux.
NOTE! The flux must be dry. Whenever possible avoid using agglomerated flux
outdoors or in a damp environment.
3. Adjust the height of the flux nozzle above the weld, to give the correct coverage
of flux. The flux cover should be sufficient to prevent the arc burning through.
Conversion of A6 TFD1 (submerged arc welding) to MIG/MAG welding
1. Replacing the wire feed motor and gearbox.
2. Reconnect the PEG1 control unit as described in the operators' manual for
PEG1.
Operating instructions for PEG1 control unit
See operators' manual for PEG1 control unit, order no. 443 392.
Careful preparation is essential for good welding results.
S
NOTE! There must not be any variation in the joint gap width.
To avoid the risk of hot cracking the weld width must be greater than the penetra-
S
tion.
Always weld a test piece with the same joint preparation and plate thickness as
S
the production work piece.
NOTE! Never make a test weld on a production work piece.
dfa4o1ea
- - 9 - -
OPERATION

Advertisement

Table of Contents
loading

This manual is also suitable for:

A6 tfd2A6 tgd1

Table of Contents