State
State
Name
S5
VID
S6
STO
S7
USB
S8
MEM 3.5
S9
MBF
S10
MEM 3.7
6.3

Known issues

The following table describes the Known issues of Dell Precision T5820XL workstation and
workarounds.
Power
Amber
Light:
Blinking
Amber
Pattern
Blinking
3.2
3 blinks
followed by a
short pause, 2
blinks, long
pause, then
repeats
3.3
3 blinks
followed by a
short pause, 3
blinks, long
pause, then
repeats
3.4
3 blinks
followed by a
short pause, 4
blinks, long
pause, then
repeats
3 blinks
followed by a
short pause, 5
blinks, long
pause, then
repeats
3.6
3 blinks
followed by a
short pause, 6
blinks, long
pause, then
repeat
3 blinks
followed by a
short pause, 7
blinks, long
pause, then
repeats
Problem
Description
Video
Video subsystem configuration activity in
l
Subsystem
progress or video subsystem failure.
failure
If customer can assist to troubleshoot,
l
narrow down the issue by removing one by
one to determine which card failed.
No Memory
If customer can assist to troubleshoot, narrow
detected
down the issue by removing the memory
module one by one to determine which one
failed and swapping to a known good memory if
available to confirm.
Storage
Possible storage device configuration in
l
Subsystem
progress or storage subsystem failure.
failure
If you can assist to troubleshoot, narrow
l
down the issue by removing the storages
on motherboard to determine which one
failed.
Memory
Memory subsystem configuration activity
l
configuration
is in progress. No memory modules were
or
detected.
incompatible
If customer can assist to troubleshoot,
l
error
narrow down the issue by removing one by
one the memory on motherboard to
determine which one failed. Also,
combining the configuration to validate
appropriate combination.
System
Fatal system board failure detected.
l
board failure
If customer can assist to troubleshoot,
l
narrow down the issue by removing one by
one the component on motherboard to
determine which one failed.
If you identified any of the components
l
failed, replace the component.
Possible
Memory subsystem configuration activity
l
memory
is in progress. Memory modules have been
failure
detected but appear to be incompatible or
in an invalid configuration.
If customer can assist to troubleshoot,
l
narrow down the issue by removing one by
one the memory on motherboard to
determine which one failed.
- 75 -