SECTION 8.5: Input Settings
Parameter
Terminal
Input 62 Setting
Terminal 4
Input SWL Setting Terminal 6
Input H Setting
Terminal 10 Reduced Open
Input SQ Setting
Terminal 9
(rev 28 and later)
Input 62 Timer
N/A
Input H Timer
N/A
Input SWL Timer
N/A
Input SQ Timer
N/A
Input 61 Circuit
N/A
Input 62 Circuit
N/A
Input 6B Circuit
N/A
Input
N/A
SWL Circuit
Input BA Circuit
N/A
6B Stop Closing
N/A
After 6B Open?
N/A
Input Setting
Default
Ext Activation
► — —
Sidelite Safety
► All Mode Activation
► Interior Activation
Sequential Input
► Exterior Activation
► Beam Sensor
► LE Approach Sensor
► Unlock Input
► Disable Power Close
► Sequential Input
► Open Slow
► Safety with Lockout
► Continuous Safety
► Reduced Opening
► Emergency Close
and Lock
► Hold Open Mode
► (Do Not Use)
Asia Only
► AsiaSpec_IntActSwgSd
► AsiaSpec_ExtActSwgSd
Same as Open Timer Same as Open Timer
0 thru 10, 12,15, 20, 25 sec
Same as Open Timer 0 thru 10, 12,15, 20, 25 sec Hold open time for Input H
Same as Open Timer Same as Open Timer
0 thru 10, 12,15, 20, 25 sec
Same as Open Timer Same as Open Timer
0 thru 10, 12,15, 20, 25 sec
► Normally Open
Normally Open
► Normally Close
Normally Open
► Normally Open
► Normally Close
► Normally Open
Normally Open
► Normally Close
Normally Open
► Normally Open
► Normally Close
Normally Close
► Normally Open
► Normally Close
No
► Yes
► No
Yes
► Yes
► No
GT1175 Slide Door Opus Control Wiring and Programming Manual
Range
► No input
► Activates in all modes but OFF
► Interior Activation (works in one-way)
► Activation on exterior
► Threshold sensor (slide door only)
► Door-mounted Sensor on approach side
► For Lock Feedback where applicable
► Turns off power close and hold close
► Takes one activation to open door and
another to close door
► Causes slow opening of the door
► Swing side header mounted sensor input
(swing door only)
► Door-mounted Sensor on pull side
► Causes unit to change to reduced open
► Forces the door to slowly close and lock
(if equipped)
► Holds door in open position
► ANSI does not allow Activation Sensor to
be mounted on the swing side of door.
► If activated, Opus will ignore the Activation
Sensor while d-oor is moving.
► This input is for the ASIAN market ONLY.
Hold open time for Input 62
Hold open time for Input SWL
Hold open time for Input SQ
Circuit logic for Input 61
Circuit logic for Input 62
Circuit logic for Input 6B
Circuit logic for Input SWL
Circuit logic for Input BA
While closing and 6B is ON at latch check, cycle
Determines door movement stop or close.
Determines door movement open or close,
after 6B.
P/N C-00391