Section 4C: RockerSwitchSettings - Nabco GT 1175 Installation Manual

With u30 microprocessor controller
Hide thumbs Also See for GT 1175:
Table of Contents

Advertisement

ElectricalInstallationManualU-30"D"Control
Part #C-00121
Table 4-2 Optex i-one
Red
U30 Harness
Black
Interior Signal
*Black/Red
Exterior Signal
Brown
Table 4-3 IXIO
Red
U30 Harness
Black
Interior Signal
*Black/Red
Exterior Signal
Brown
Section 4c: Rocker Switch Settings
OFF = Not switched to COMMON
Rocker Switch
Key Switch
Night
Night
Mode
Mode
Hold Open
Two Way
Auto
4-12
Common
+12 VDC
Common
+12 VDC
Wire
Wire
OFF
ON
M0
M1
H.O.
ON
ON
OFF
OFF
Red
Extension Harness
Yellow
Gray
Red
Extension Harness
Yellow
Gray
ON = Switched to COMMON (RED 7)
Wire
X Sensors on Terminal (3) and (8) can not open the door
H
while door is closed.
-
X Sensors on Terminal (3) and (8) will provide threshold
safety when door is in any position other than closed.
X Electric Lock remains locked unless an activation signal
is given from a device (such as card reader, key switch,
wall plate, etc.): connected in one of two ways:
1.►Between Common and MO (7)
a.►This only works when door is in "Night" mode
2.►Between Common and SLS (11)
a.►This only works if the SLS is programmed for
activation devices.
Note: Consult the U30 Programming Manual for details;
X No activation needed when "Hold Open" is selected.
(P/N 15-9000-30).
Slide door is held open.
-
X Electric Lock is always unlocked.
X Sensors on Terminal (3) and (8) can both open
the door.
-
X Electric Lock is always unlocked.
www.NabcoEntrances.com
**Gray and White
Optex i-one Harness
Yellow
Gray
**Red and White and Brown
IXIO Harness
Green and Blue
Black
Description
IdentifyOperatingWires
Rev. 8-25-16