Nabco GT1175 Wiring And Programming Manual page 31

Slide door opus control
Hide thumbs Also See for GT1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-11-21
Opus Error Msg
No Motor
Motor disconnection error
Thrml Warning
Thermal-on warning
No Load
No load error
Electrical Lock
Electrical lock error
61 Sensor
T3:61 sensor error
62 Sensor
T4:62 sensor error
6B Sensor
T5:6B sensor error
SWL Sensor
T6:SWL sensor error
NET-HT Error Msg
GT1175 Slide Door Opus Control Wiring and Programming Manual
Error Messages
► Check all connections between the Control and Motor.
► Check all connections between the Control and Motor.
► Cool down the motor, and adjust the recycle sensitivity and Open/
Close speed.
► Check operator (gear cracked, belt skipped).
► Check lock settings and wiring.
► Ensure lock delay is long enough, and not set to (After Lock Input).
► Ensure no programmable inputs are set to "Unlock Input" assuming
there is no lock feedback.
► Check Sensor wiring.
► Check Settings on Sensor and/or Control related to
Sensor Monitoring.
► Try a new Sensor.
Resolution
P/N C-00391
31 of 31

Hide quick links: