SECTION 3.9: Relay Output Terminal Strip
COM
Common Input
SECTION 3.10: CAN Bus Communication
Used to connect Sim Pair, Astragal, Sequencing and the NET-HT Cable when programming.
SECTION 3.11: Simultaneous Pair
Bi-Part Units installed with panels larger and/or heavier than standard panels, require (2) Drivetrains. (2) Drivetrains require (2) Opus
Controls. (2) Opus Controls installed inside (1) Header must be programmed as a Sim-Pair (same as a swing door). (2) Opus Controls
are installed inside the Header and programmed as a Sim-Pair at the NABCO Factory.
CHAPTER 4: LCD CATEGORY SCREENS
LEVEL 1
UNIT SPECS
LEVEL 3
Short
Se ng Category
Push
LEVEL 4
Parameter
Base Se ng
Movement Se ng
(Rotate Rotary Dial)
Op onal Se ng
Output Se ng
Input Se ng
History Data
Push and Hold Rotary Dial (2 Sec.)
SECTION 4.1 Level One: Specification Screens
UNIT SPECS
GT1175 Opus Slide
Type:
GT710 Swing
Status:
Slow Closing
Fully Closed
Error:
-----
Ac va on: IN EXT
Posi on:
> > > > > > >
Other:
BA 6B SLS
Keep Pushing Switch
=> Se ng Mode
DN 2430
N.C.
Normally Closed Contact
ERROR
Rotate
Rotate
Dial
Dial
Rotate Dial to navigate screen. Short Push Dial to select
Operator Type/Low or Full Energy/Handing/Encoder
Open Speed/Back Check Speed/Back Check Range/Close Speed/Latch Check Speed/
Latch Check Range/Open Timer/Reac on Power/Open Recycle Sens/Close Recycle Sens/
A er Open Recycle
Hold Close Force/Power Close Range/Manual Open Func on/Manual Open Sens/Manual
Open Timer/BCHK Lockout Angle/LCHK Lockout Angle/Stop Force adjustment/SimPair Se ng
Output1 Se ng/Output2 Se ng/RelayOutput3 Se ng/Open Delay Timer/
Sequence Delay Timer/Lock Condi on
Input 62 Se ng/Input 62 Open Timer/Input H Se ng/Input H Open Timer/Input 61 Circuit/
Input 62 Circuit/Input 6B Circuit/Input SWL Circuit/Input BA Circuit/6B Stop Closing/A er 6B
Open?/61 Monitoring/62 Monitoring/6B Monitoring/SWL Monitoring
Opera on Cnt/Open Recycle Cnt/Close Recycle Cnt/Latest Recycle Posi on
ERROR SPECS
Error Screen
Mfg: 11/2016
Rev.B:21
Rotate
Dial
GT1175 Slide Door Opus Control Wiring and Programming Manual
Relay Output 3
N.O.
Normally Open contact for Sensor Monitoring
ANSI
TERMINAL
Rotate
Dial
Op ons
ANSI SPECS
ANSI specs (reference)
Opening Time to 80 deg
Closing Time to LCHK
LCHK to FullClosed
Rotate
Dial
LEVEL 2
Passcode
Go to Se ng Menu
Long
Stroke Learning
Push
Yes No
DN 1334
Figure 2 LCD Screen Transition
TERMINAL SPECS
Terminal
8
BA
1 12VDC
9
SQ
2 GND
10 Mul
3 61
11 M0
4 62
12 M1
5 6B
13 Out3
6 SWL
14 GND
7 Out2
Rotate
Figure 3 Level One Screens
Dial
P/N C-00391
7 of 31