Section 8.3: Optional Settings - Nabco GT1175 Wiring And Programming Manual

Slide door opus control
Hide thumbs Also See for GT1175:
Table of Contents

Advertisement

www.NabcoEntrances.com
Rev. 8-11-21
Parameter
Close Recycle
Yes
Reopen
No
SECTION 8.3: Optional Settings
Parameter
Hold Close Force
Sim Pair Setting
Flip Screen
Range
Default
Yes
Determines what happens after a recycle while closing cycle.
► Yes = Door re-opens
► No = Door stops then slowly closes
Range
0 - 3
Single Door
Normal Sim Pair
Double Egress
Overlap Sim Pair
Yes
No
GT1175 Slide Door Opus Control Wiring and Programming Manual
Movement Setting
Optional Setting
Default
0
0
OFF
3
Strongest Hold Close force
Single
Select type of Door
Door
If selected; before returning to last screen, option to copy
settings to other Control is given.
The Activation signal (only) is shared between doors. All other
signals are independent.
► Overlap Sim Pair is for an Astragal Application.
► Opus Control connected to door that must open first:
 1. Have activation signals connected to it
 2. Be set to "Overlap Sim Pair"
► The delayed control will be set to "Normal Sim Pair"
► Latch Check range is wider than normal setting.
► If selected; before returning to last screen, the option to
copy settings to the other Control is given
No
Choose Yes if Opus is installed upside down.
LCD will flip right side up when Control is upside down.
Description
Description
P/N C-00391
13 of 31