Menu Descriptions

Primary Timing Mode Menu

The Primary Timing Mode menu (see
the selected DS1 port (1-4 on the MX410 and 1-12 on the MX412).
Active Alarms: CRITICAL MAJOR
Selection :
The Primary Timing Mode menu options are shown in
Option
Description
1
Internal
2
DS1 1
3
DS1 2
4
DS1 3
5
DS1 4
The entire MX410/MX412 is timed from a single source and all
transmitters are synchronized. Any device attached to the MX410/
MX412 should be placed in loop or line timing mode, unless it is
providing timing. If an attached device is providing timing, the
MX410/MX412 must be configured to use this interface as its pri-
mary timing source. If the MX410/MX412 is set for internal timing,
all devices connected to it must be set to loop or line timing.
5-20 PRELIMINARY
Figure
Primary Timing Mode : Internal
1 - Internal
2 - DS1 1
3 - DS1 2
4 - DS1 3
5 - DS1 4

Figure 5-10. Primary Timing Mode Menu

Table 5-7. Primary Timing Mode Menu Options

Function
This option sets the timing mode to internal.
This option sets the timing mode to DS1 1.
This option sets the timing mode to DS1 2.
This option sets the timing mode to DS1 3.
This option sets the timing mode to DS1 4.
5-10) is used to set the primary timing mode for
MX410
ID:
'?' - System Help Screen