Hameg HMC8012 Programmer's Manual page 49

Scpi commands
Hide thumbs Also See for HMC8012:
Table of Contents

Advertisement

SCPI Commands HMC8012
[SENSe:]FREQuency:APERture? [{MIN|MAX}]
Returns the gate time of the frequency measurement function in AC V / AC I mode.
Return values:
<GateTime>
S C P I P r o g r a m m e r s M a n u a l
[SENSe:]FREQuency:CURRent:RANGe:AUTO <Mode>
S C P I P r o g r a m m e r s M a n u a l
S C P I P r o g r a m m e r s M a n u a l
Activates or disables the auto range mode of the AC I measurement function for frequency measurements.
Parameters:
<Mode>
[SENSe:]FREQuency:CURRent:RANGe:AUTO?
Returns the auto range state of the AC I measurement function for frequency measurements.
Parameters:
<Mode>
[SENSe:]FREQuency:CURRent:RANGe[:UPPer] {<Current_Range>|MIN|MAX|DEF}
:ACQuire
Sets the current range of the AC I measurement function for frequency measurements.
:CHAN1OFFSet
Parameters:
<Current_Range>
[SENSe:]FREQuency:CURRent:RANGe[:UPPer]? [{MIN|MAX}]
Returns the current range of the AC I measurement function for frequency measurements.
Return values:
<Current_Range>
HAMEG Instruments GmbH • Industriestr. 6 • D-63533 Mainhausen • Deutschland
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Geschäftsführer: Dipl.-Ing. Holger Asmussen, Dipl.-Ing. Andre Vander Stichelen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
1.00000000E-02, 1.00000000E-01, 1.00000000E+00
MIN:
1.00000000E-02
MAX:
1.00000000E+00
ON | OFF | 1 | 0
ON:
Activates the auto range mode of the AC I measurement function
OFF:
Disables the auto range mode of the AC I measurement function
1:
Activates the auto range mode of the AC I measurement function
0:
Disables the auto range mode of the AC I measurement function
*RST:
ON
1 | 0
1:
Auto range mode of the AC I measurement function is activated
0:
Auto range mode of the AC I measurement function is disabled
20mA, 200mA, 2A, 10A
:DISPlay
MIN:
20mA
MAX:
10A
DEFault:
20mA
*RST:
AUTO
:HCOPy
*ESR?
20mA, 200mA, 2A, 10A
MIN:
2.00000000E-02
MAX:
1.00000000E+01
DEFault:
2.00000000E-02
H M O S e r i e s
H M S S e r i e s
H M S S e r i e s
Firmware Version: 01.020 and later
Firmware Version: 01.020 and later
Firmware Version: 03.00 and later
:MEASure
:LOGic:SIZE
*OPC?
HMO352x, HMO2524
HMO72x ... HMO202x
:POD1
:SYSTem
*SRE?
Subject to change without notice
Subject to change without notice
Subject to change without notice
English
English
English