SCPI Commands HMC8012
[SENSe:]DIODe:BEEPer[:STATe]?
Returns the beeper function state of the diode measurement function.
Return values:
<State>
S C P I P r o g r a m m e r s M a n u a l
Frequency configuration commands
S C P I P r o g r a m m e r s M a n u a l
S C P I P r o g r a m m e r s M a n u a l
CONFigure:FREQuency[:VOLTAGE] .......................................................................... 48
CONFigure:FREQuency:CURRent ............................................................................. 48
[SENSe:]FREQuency:APERture {<Seconds>|MIN|MAX|DEF} ................................... 48
[SENSe:]FREQuency:APERture? [{MIN|MAX}] ........................................................... 49
[SENSe:]FREQuency:CURRent:RANGe:AUTO <Mode> ........................................... 49
[SENSe:]FREQuency:CURRent:RANGe:AUTO? ........................................................ 49
[SENSe:]FREQuency:CURRent:RANGe[:UPPer] {<Current_Range>|MIN|MAX|DEF} 49
[SENSe:]FREQuency:CURRent:RANGe[:UPPer]? [{MIN|MAX}] ................................. 49
[SENSe:]FREQuency:VOLTage:RANGe:AUTO <Mode> ............................................ 50
[SENSe:]FREQuency:VOLTage:RANGe:AUTO? ......................................................... 50
[SENSe:]FREQuency:VOLTage:RANGe[:UPPer] {<Voltlage_Range>|MIN|MAX|DEF} 50
[SENSe:]FREQuency:VOLTage:RANGe[:UPPer]? [{MIN|MAX}] .................................. 50
CONFigure:FREQuency[:VOLTAGE]
Configures the instrument for frequency measurements, but does not initiate a measurement. Use the READ? com-
mand to query the frequency measurement value or the CONF? command to query the frequency function configurati-
on in AC V mode.
CONFigure:FREQuency:CURRent
Configures the instrument for frequency measurements, but does not initiate a measurement. Use the READ? com-
:ACQuire
mand to query the frequency measurement value or the CONF? command to query the frequency function configurati-
on in AC I mode.
:CHAN1OFFSet
[SENSe:]FREQuency:APERture {<Seconds>|MIN|MAX|DEF}
Sets the gate time of the frequency measurement function in AC V / AC I mode.
Parameters:
<Seconds>
HAMEG Instruments GmbH • Industriestr. 6 • D-63533 Mainhausen • Deutschland
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Geschäftsführer: Dipl.-Ing. Holger Asmussen, Dipl.-Ing. Andre Vander Stichelen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
1 | 0
1
ON - beeper of the diode measurement function is activated
0
OFF - beeper of the diode measurement function is disabled
:DISPlay
10ms, 100ms, 1s
:HCOPy
MIN:
10ms
MAX:
1s
DEFault: 1s
*RST:
1s
*ESR?
H M O S e r i e s
H M S S e r i e s
H M S S e r i e s
Firmware Version: 01.020 and later
Firmware Version: 01.020 and later
Firmware Version: 03.00 and later
:MEASure
:LOGic:SIZE
*OPC?
HMO352x, HMO2524
HMO72x ... HMO202x
:POD1
:SYSTem
*SRE?