SCPI Commands HMC8012
Diode configuration commands
CONFigure:DIODe ..................................................................................................... 47
[SENSe:]DIODe:THReshold {<Threshold>|MIN|MAX|DEF} ........................................ 47
[SENSe:]DIODe:THReshold? [{MIN|MAX|DEF}] ......................................................... 47
[SENSe:]DIODe:BEEPer[:STATe] {ON|OFF} ................................................................ 47
[SENSe:]DIODe:BEEPer[:STATe]? .............................................................................. 48
S C P I P r o g r a m m e r s M a n u a l
CONFigure:DIODe
S C P I P r o g r a m m e r s M a n u a l
S C P I P r o g r a m m e r s M a n u a l
Configures the instrument for diode measurements, but does not initiate a measurement. Use the READ? command
to query the diode measurement value or the CONF? command to query the general function configuration.
[SENSe:]DIODe:THReshold {<Threshold>|MIN|MAX|DEF}
Sets the threshold of the diode measurement function. In this case, the instrument does not switch into continuity
mode. For activating the continuity measurement function use the FUNC command.
Parameters:
<Threshold>
[SENSe:]DIODe:THReshold? [{MIN|MAX|DEF}]
Returns the threshold of the diode measurement function.
Return values:
<Threshold>
:ACQuire
:CHAN1OFFSet
[SENSe:]DIODe:BEEPer[:STATe] {ON|OFF}
Turns the beeper function for diode measurements on or off.
Parameters:
<State>
HAMEG Instruments GmbH • Industriestr. 6 • D-63533 Mainhausen • Deutschland
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
HAMEG Instruments GmbH • Industriestraße 6 • D-63533 Mainhausen
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Tel.: +49 (0) 6182 800 0 • Fax: +49 (0) 6182 800 100 • E-Mail: info@hameg.com
Geschäftsführer: Dipl.-Ing. Holger Asmussen, Dipl.-Ing. Andre Vander Stichelen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
Geschäftsführer: Dipl.-Ing. Holger Asmussen • AG Offenbach am Main HRB 41200
0V to 5V (adjustable in 1µV steps)
MIN:
0V
MAX:
5V
DEFault: 700mV
*RST:
700mV
0V to 5V
MIN:
0.00000000E+00
MAX:
4.94999981E+00
DEFault: 6.99999988E-01
:DISPlay
ON | OFF
:HCOPy
ON:
Beeper of the diode measurement function is activated
OFF:
Beeper of the diode measurement function is disabled
*RST:
OFF
*ESR?
H M O S e r i e s
H M S S e r i e s
H M S S e r i e s
Firmware Version: 01.020 and later
Firmware Version: 01.020 and later
Firmware Version: 03.00 and later
:MEASure
:LOGic:SIZE
*OPC?
HMO352x, HMO2524
HMO72x ... HMO202x
:POD1
:SYSTem
*SRE?
Subject to change without notice