CHAPTER 8 ELECTRICAL
6.Wiring connection
Check the connection of the entire
lighting system
check the condition of each of the
lighting system's circuits
Refer to "LIGHTING SYSTEM CHECK"
LIGHT SYSTEM CHECK
1. If the high/low beam light and direction indicator fail to come on
1.Blub and bulb socket
CHECK
2. Voltage
Connect the pocket tester (DC20V) to
the high/low beam light and direction
indicator light couplers.
A When the High/low beam switch is on
high beam
High beam light:
Tester (+) lead →Blue lead
Tester negative (-) lead →Green lead
B When the High/low beam switch on low
beam
Low beam light:
Tester (+) lead →White lead
Tester negative (-) lead →Green lead
C When the High/low beam switch on
position light
Front/rear position light:
Tester (+) lead →Black lead
Tester negative (-) lead →Green lead
D When the turn switch on turn right
position
Front/rear turn right light(LED)
Tester (+) lead →Light Blue lead
Tester negative (-) lead →Green lead
E When the turn switch on turn left
position
BUCK 450 SERVICE MANUAL 20.0
POOR CONNECTIONS
correct
NO CONTINUITY
Replace the bulb and/ or bulb
socket
OUT OF SPECIFICATION
The wiring circuit from the main
switch to bulb socket connector
is faulty. Repair
CHAPTER 8 ELECTRICAL PAGE 8- 24