3.3.6. Alarms

Allows you to set the audio level threshold (overload and silence detection) for each
channel. Select audio level and alarm in SNMP menu to generate the appropriate
Trap.
3.3.7. Date & Time
Allows you to set the Time zone and Clock-Reference and to synchronize date and
time of the device with your PC time.
Clock-Reference options: [Internal] [SNTP]
When set to [Internal], the date and time will be set once and you have to
synchronize manually from time to time.
When set to [SNTP], the time and date will be updated periodically. The
synchronisation interval can be configured in the sub-menu SNTP settings.
Hint: You have to configure the gateway in the Network menu first.
Sub-menu SNTP settings items are:
Primary Time Server
Secondary Time Server
Synchronize Interval[min]
After changing the Clock-Reference option, click the save button first and then
synchronize.

3.3.8. Profiles

This screen allows you to save and restore the current configuration. This is
recommended before updating your firmware. Refer to section 5 System Update.
Click the "Download" button and save the current configuration on your PC. After
firmware update, you can restore your configuration by entering the file path and
clicking the "Upload" button.
Restart Device → save received configuration and restart with new configuration
Cancel → return to previous page, received configuration will be discarded
(default value: 60)