5.5.10. Connector X1405 (Matrix Keyboard)
MKBD_O0...MKBD_O7
Matrix keyboard outputs. Maximal output voltage is 3.3V DC.
MKBD_I0...MKBD_I7
Matrix keyboard inputs. Maximal input voltage is 3.3V DC.
5.5.11. Connector X1404 (Touch Panel)
YB
Touch panel bottom driving signal.
SYB
Touch panel bottom sensing signal. For 4-wire touch panels connect to YB.
YT
Touch panel top driving signal.
SYT
Touch panel top sensing signal. For 4-wire touch panels connect to YT.
XL
Touch panel left driving signal.
SXL
Touch panel left sensing signal. For 4-wire touch panels connect to XL.
XR
Touch panel right driving signal.
SXR
Touch panel right sensing signal. For 4-wire touch panels connect to XR.
TRB#
Touch panel right mouse button. Open collector input. Maximal input voltage is 5V DC.
TLB#
Touch panel left mouse button. Open collector input. Maximal input voltage is 5V DC.
ePanel-mgx
Page 22 of 45 Pages