When the Express XL/XLT powers up, it performs an internal self-test. This
takes about 10 seconds. At the end of the test, the PWR LED should remain on.
IF SELF-TEST FAILS
If the PWR LED is not on or continuously flashes, the following steps will ver-
ify whether or not the problem can be fixed locally.
1.
Ensure the Express XL/XLT is receiving power.
2.
Power off the Express XL/XLT while holding down SELECT and TEST;
then power back up. This will reset all internal settings to their factory de-
fault.
3.
Continue holding the SELECT and TEST buttons until the Loop LED
flashes once.
4.
If the Express XL/XLT still does not pass self-test, call ADTRAN Technical
Support for assistance. See the inside back cover of this manual for infor-
mation on contacting ADTRAN.

IF THE EXPRESS XL/XLT DOES NOT READ READY

When the Express XL/XLT has been set up and connected to a line, but the
Loop LED does not remain on after a few minutes, proceed with the following
steps:
1.
Cycle power on the Express XL/XLT, leaving it off for a minimum of two
seconds; then turn the power on for one minute to ensure the Loop LED
still doesn't turn on.
61200070L1-1
Troubleshooting
Express XL/XLT User Manual
Chapter 4
107