ADTRAN NetVanta 3200 series Hardware Installation Manual

ADTRAN NetVanta 3200 series Hardware Installation Manual

Hide thumbs Also See for NetVanta 3200 series:
Table of Contents

Advertisement

NetVanta 3200/3300/3400 Series Routers
1203860G1
1203870G1
1203980G1
1202880E1
1202820G1
1200821E1
1200823G1
1200824G1
1200861L1
1202862L1
1200862L2#NEBS
1202863L1
1202872L1
1200868E1/L1
1200878E1/L1
1200866E1
1200936E1
1200937E1
1202869E1
1202889E1
1702803F1
1200864L1
1200865L1
1200875L1
4200825E1#120
4200825E1#240
1950860G2
4200368E1/L1
1200819E1
1200827E1
61200860L1-34AB
October 2012
Hardware Installation Guide
NetVanta 3200
NetVanta 3205 (AC Version)
NetVanta 3205 (DC Version)
NetVanta 3305
NetVanta 3430
NetVanta 3448
NetVanta 3450
NetVanta 3458
NetVanta 56K/64K Network Interface Module
NetVanta T1/FT1 Network Interface Module
NetVanta T1/FT1 NEBS Network Interface Module
NetVanta T1/FT1 + DSX-1 Network Interface Module
NetVanta Dual T1 Network Interface Module
NetVanta E1/FE1 Network Interface Module
NetVanta E1/FE1 + G.703 Network Interface Module
NetVanta Serial Network Interface Module
NetVanta SHDSL Network Interface Module, Annex A
NetVanta SHDSL Network Interface Module, Annex B
NetVanta ADSL Network Interface Module, Annex A
NetVanta ADSL Network Interface Module, Annex B
USB WWAN Network Interface Module (NetVanta 3305/3430/3448/3450/3458)
NetVanta Analog Modem Dial Backup Interface Module
NetVanta ISDN BRI Dial Backup Interface Module
NetVanta ISDN S/T Dial Backup Interface Module
Octal PoE Upgrade Bundle (Module and 120 VDC Power Supply) (NetVanta 3448/3458)
Octal PoE Upgrade Bundle (Module and 240 VDC Power Supply) (NetVanta 3448/3458)
Enhanced Feature Pack Software for IPsec VPN Upgrade (NetVanta 3200/3205/3305)
Enhanced Feature Pack (Hardware and Software) for IPsec VPN Upgrade (NetVanta 3305)
CompactFlash
®
1 GB (NetVanta 3430/3448 only)
NetVanta 3430/3448 Rackmount Kit

Advertisement

Table of Contents
loading

Summary of Contents for ADTRAN NetVanta 3200 series

  • Page 1 NetVanta 3200/3300/3400 Series Routers Hardware Installation Guide 1203860G1 NetVanta 3200 1203870G1 NetVanta 3205 (AC Version) 1203980G1 NetVanta 3205 (DC Version) 1202880E1 NetVanta 3305 1202820G1 NetVanta 3430 1200821E1 NetVanta 3448 1200823G1 NetVanta 3450 1200824G1 NetVanta 3458 1200861L1 NetVanta 56K/64K Network Interface Module 1202862L1 NetVanta T1/FT1 Network Interface Module 1200862L2#NEBS...
  • Page 2 To the Holder of the Manual The contents of this manual are current as of the date of publication. ADTRAN reserves the right to change the contents without prior notice. In no event will ADTRAN be liable for any special, incidental, or consequential damages or for commercial losses even if ADTRAN has been advised thereof as a result of issue of this publication.
  • Page 3 NetVanta 3200/3300/3400 Series Conventions Conventions Notes provide additional useful information. Cautions signify information that could prevent service interruption or damage to the equipment. Warnings provide information that could prevent injury or endangerment to human life. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 4 Additional safety guidelines, such as Waste Electrical and Electronic Equipment (WEEE), are given in the document NetVanta Safety and Regulatory Information available at https://supportforums.adtran.com. Save These Important Safety Instructions Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 5 Advance notification and the opportunity to maintain uninterrupted service are given. 4. If experiencing difficulty with this equipment, please contact ADTRAN for repair and warranty information. The telephone company may require this equipment to be disconnected from the network until the problem is corrected, or it is certain the equipment is not malfunctioning.
  • Page 6 EN 55022 Class A EN 55022 Class A 1200875L1 ISDN S/T DIM EN 55024 EN 55024 EN 55024 EN 55024 1202368L1 VPN Accelerator Card FCC Part 15 Class A EN 55022 Class A EN 55024 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 7 Denial of Service (DoS) attacks, loss or theft of data, and the unauthorized or illegal use of said equipment. ADTRAN OFFERS NO WARRANTIES, EITHER EXPRESSED OR IMPLIED, REGARDING THE PREVENTION, DETECTION, OR DETERRENCE OF TOLL FRAUD, NETWORKING ATTACKS, OR UNAUTHORIZED, ILLEGAL, OR IMPROPER USE OF ADTRAN EQUIPMENT OR SOFTWARE.
  • Page 8 Service and Warranty NetVanta 3200/3300/3400 Series Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 9: Table Of Contents

    NetVanta SHDSL NIM, Annex A (P/N 1200936E1) ........53 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 10 Appendix A. Connector Pin Definitions ..........85 Copyright © 2012 ADTRAN, Inc.
  • Page 11 Figure 43. NetVanta Octal PoE Upgrade Installation ........83 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 12 List of Figures NetVanta 3200/3300/3400 Series Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 13 ISDN S/T DBU Connector Pinouts ......... . . 91 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 14 List of Tables NetVanta 3200/3300/3400 Series Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 15: Introduction

    For information on switch configuration for a specific application, refer to the configuration guides provided on ADTRAN Support Community. For details on the command line interface (CLI), refer to the Command Reference Guide. All other related documents are also available online at http://supportforums.adtran.com. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 16: Physical Descriptions

    • Compatible with ISsec VPN-equipped devices • IP encapsulation over Frame Relay (RFC 1490) • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Standards-based eBGP/iBGP, OSPF, RIP, static routing and bridging protocols •...
  • Page 17: Netvanta 3200 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 18: Netvanta 3200 Front Panel Design

    10Base-T or 100Base-T with a single connector • Auto-negotiation • CSMA/CD • IEEE 802.3 compatibility CONSOLE Interface CONSOLE interface is an EIA-232 serial port (DCE) that provides for local management and configuration (via a DB-9 female connector) Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 19: Netvanta 3205

    Optional ISsec VPN supporting DES/3DES/AES encryption • IP encapsulation over Frame Relay (RFC 1490) • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Standards-based eBGP/iBGP, OSPF, RIP, static routing and bridging protocols •...
  • Page 20: Netvanta 3205 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 21: Netvanta 3205 Front Panel Design

    NetVanta 3205 Rear Panel Interfaces and LEDs SLOT 1 NET/DBU Option Slot option slot supports various NIM plug-in option modules. These option SLOT 1 NET/DBU modules are described in the section Option Modules on page 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 22: Netvanta 3305

    Modular IP access routers for MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, PPPoE, ATM, and HDLC networks • Integrated IP router with bridging • IP encapsulation over Frame Relay (RFC 1490) • ADTRAN Operating System (AOS) command line interface (CLI) Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 23 Refer to Using a USB Cellular Modem with the NetVanta USB WWAN NIM on page 76 for details on installing and removing a USB cellular modem from the USB WWAN NIM. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 24: Netvanta 3305 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 25: Netvanta 3430

    G.703, or ADSL (Annex A or Annex B), SHDSL (Annex A or Annex B), serial, or USB WWAN • Modular IP access routers for MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, PPPoE, ATM, and HDLC networks • High-performance processor • Hardware encryption engine embedded • On-board Flash memory 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 26 SODIMM slot • Two integrated 10/100Base-T WAN/LAN ports • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Standards-based BGP, OSPF, RIP, static routing, and bridging protocols •...
  • Page 27: Netvanta 3430 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 28: Netvanta 3430 Front Panel Design

    In addition to the LEDs, this front panel contains a slot for nonvolatile configuration storage and CompactFlash compressed code storage. ADTRAN supports only ADTRAN-provided CompactFlash (16 MB to 1 GB) (refer to the list of part numbers on the front cover). Refer to Installing a CompactFlash Card on page Figure 8.
  • Page 29: Netvanta 3448

    Integrated 8-port fully-managed Ethernet switch • Optional Octal PoE upgrade for switch ports to provide (802.3af/Legacy) PoE capability • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Modular IP access routers for MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, PPPoE, ATM, and HDLC networks •...
  • Page 30: Netvanta 3448 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 31: Netvanta 3448 Front Panel Design

    40. In addition to the LEDs, this front panel contains a slot for nonvolatile configuration CompactFlash storage and compressed code storage. ADTRAN supports only ADTRAN-provided CompactFlash (16 MB to 1 GB) (refer to the list of part numbers on the front cover). Refer to Installing a CompactFlash Card on page Figure 10.
  • Page 32: Netvanta 3448 Rear Panel Design

    Supplying Power to the Unit on page 69 for connection details. NetVanta 3450 The NetVanta 3450 is a high-performance, modular IP access router designed for cost-effective branch office connectivity over MPLS, Frame Relay, multilink Frame Relay, PPP, MLPPP, or Ethernet networks. Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 33: Netvanta 3450 Features And Specifications

    Expandable memory storage via a CompactFlash card slot on the front panel • Two integrated 10/100Base-T WAN/LAN ports • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Standards-based BGP, OSPF, RIP, static routing, and bridging protocols •...
  • Page 34: Netvanta 3450 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 35: Netvanta 3450 Front Panel Design

    The front panel contains a slot for nonvolatile configuration storage and compressed code CompactFlash storage. ADTRAN supports only ADTRAN-provided CompactFlash (16 MB to 1 GB) (refer to the list of part numbers on the front cover). Refer to Installing a CompactFlash Card on page NetVanta 3450 Rear Panel Design The NetVanta 3450 rear panel is shown below with a module installed.
  • Page 36: Netvanta 3458

    Expandable memory storage via a CompactFlash card slot on the front panel • Two integrated 10/100Base-T WAN/LAN ports • ADTRAN Operating System (AOS) command line interface (CLI) • User-friendly, Web-based graphical user interface (GUI) • Standards-based BGP, OSPF, RIP, static routing, and bridging protocols •...
  • Page 37: Netvanta 3458 Shipping Contents

    After unpacking the unit, inspect it for possible shipping damage. If the equipment has been damaged in transit, immediately file a claim with the carrier and contact ADTRAN Customer Service (refer to the Support page on the ADTRAN website at http://www.adtran.com/support).
  • Page 38: Netvanta 3458 Front Panel Design

    The front panel contains a slot for nonvolatile configuration storage and compressed code CompactFlash storage. ADTRAN supports only ADTRAN-provided CompactFlash (16 MB to 1 GB) (refer to the list of part numbers on the front cover). Refer to Installing a CompactFlash Card on page Copyright ©...
  • Page 39: Netvanta 3458 Rear Panel Design

    IEEE 802.3 compatibility Power Connection All of the 1U-high products have universal power supplies and are shipped with the appropriate cable. Please refer to Supplying Power to the Unit on page 69 for connection details. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 40: Netvanta 3000 Series Front Panel Leds

    (not present on all Green (solid) The port is enabled and the link is up. units) Amber (flashing) The port has activity (transmit or receive). No encrypted traffic. (not present on all Encrypted traffic present. units) Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 41: Option Modules

    Refer to Using a USB Cellular Modem with the NetVanta USB WWAN NIM on page 76 for details on installing and removing a USB cellular modem from the USB WWAN NIM. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 42: Option Module Shipping Contents

    Shipments of the Dual T1 NIM include the following items: • Dual T1 Network Interface Module • Quick start guide • Two 15-foot RJ-45 to RJ-45 cable (ADTRAN P/N 3125M008@A) NetVanta E1/FE1 NIM (1200868E1/L1) Shipments of the E1/FE1 NIM include the following items: • E1/FE1 Network Interface Module •...
  • Page 43 • Serial Network Interface Module • Quick start guide • 15-foot RJ-45 to RJ-45 cable (ADTRAN P/N 3125M008@A) NetVanta SHDSL NIM, Annex A (1200936E1) Shipments of the SHDSL NIM, Annex A, include the following items: • SHDSL Network Interface Module •...
  • Page 44 • Quick start guide • 7-foot RJ-45 to RJ-11 cable (ADTRAN P/N 3125M007@A) Option modules are intended to be serviced by qualified service personnel only. System bundles are shipped with a base unit, a network interface module, and other appropriate contents based on the system-level solution ordered.
  • Page 45: Network Interface Modules

    • Storage Temperature: -20°C to 70°C Clock Source • Relative Humidity: Up to 95 percent, • Network noncondensing • Internal Physical Diagnostics • Dimensions: 2.75-inch W x 4.25-inch D • CSU and DSU Loopbacks 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 46: Netvanta T1/Ft1 Nim (P/N 1202862L1)

    Operating Temperature: 0°C to 50°C • Connector: RJ-48C • Storage Temperature: -20°C to 70°C • Relative Humidity: Up to 95 percent, Clock Source • Network noncondensing • Internal Physical • Dimensions: 2.75-inch W x 4.25-inch D Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 47: Netvanta T1/Ft1 Nebs Nim (P/N 1200862L2#Nebs)

    • Operating Temperature: 0°C to 50°C Clock Source • Storage Temperature: -20°C to 70°C • Network • Relative Humidity: Up to 95 percent • Internal noncondensing Physical • Dimensions: 2.75-inch W x 4.25-inch D 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 48: Netvanta T1/Ft1 + Dsx-1 Nim (P/N 1202863L1)

    Line Codes: AMI, B8ZS • DSX-1 Interface to PBX Physical • Dimensions: 2.75-inch W x 4.25-inch D • Framing: D4 (SF) or ESF • Line Length: 0 to 655 feet and -7.5 dB • Connector: RJ-48C Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 49: Netvanta Dual T1 Nim (P/N 1200872L1/1202872L1)

    The 1200872L1 Dual T1 module supports the analog modem (1200864L1), ISDN BRI (1200865L1), and ISDN S/T (1200875L1) DIMs for dial backup applications. The 1202872L1 Dual T1 module supports only the analog modem (1200864L1) DIM for dial backup applications. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 50: Netvanta E1/Fe1 Nim (P/N 1200868E1/L1)

    (Telecommunications exemption) • Network • Internal Environmental • Operating Temperature: 0°C to 50°C • Storage Temperature: -20°C to 70°C • Relative Humidity: Up to 95 percent, noncondensing Physical • Dimensions: 2.75-inch W x 4.25-inch D Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 51: Netvanta E1/Fe1 + G.703 Nim (P/N 1200878E1/L1)

    Storage Temperature: -20°C to 70°C • Capacity: 1 to 31 timeslots • Relative Humidity: Up to 95 percent, • Connector: RJ-48C noncondensing Clock Source Physical • Network • Dimensions: 2.75-inch W x 4.25-inch D • Internal • Through 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 52: Netvanta Serial Nim (P/N 1200866E1)

    EIA 530 interface. This module supports rates up to a maximum of 10 Mbps. An additional V.35 (ADTRAN P/N 1200873L1), X.21 (ADTRAN P/N 1200874L1), or EIA 530 (ADTRAN P/N 1200883L1) cable is required (see Caution below). See Table A-14 on page 90 for the serial connector pinouts, and Table A-15 on page 91 for the DBU connector pinouts.
  • Page 53: Netvanta Shdsl Nim, Annex A (P/N 1200936E1)

    • Storage Temperature: -20°C to 70°C • Relative Humidity: Up to 95 percent, Clock Source • CPE Operating Mode: Network noncondensing • CO Operating Mode: Internal Physical • Dimensions: 2.75-inch W x 4.25-inch D 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 54: Netvanta Shdsl Nim, Annex B (P/N 1200937E1)

    • Storage Temperature: -20°C to 70°C Clock Source • CPE Operating Mode: Network • Relative Humidity: Up to 95 percent, • CO Operating Mode: Internal noncondensing Physical • Dimensions: 2.75-inch W x 4.25-inch D Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 55: Netvanta Adsl Nim, Annex A (P/N 1202869E1)

    ATM Forum UNI 3.1/4.0 PVC • Relative Humidity: Up to 95 percent, • ATM class of service (UBR) noncondensing • ATM F5 OAM Physical • Up to 16 virtual circuits • Dimensions: 2.75-inch W x 4.25-inch D 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 56: Netvanta Adsl Nim, Annex B (P/N 1202889E1)

    Storage Temperature: -20°C to 70°C • ATM class of service (UBR) • Relative Humidity: Up to 95 percent, • ATM F5 OAM noncondensing • Up to 16 virtual circuits Physical • Dimensions: 2.75-inch W x 4.25-inch D Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 57: Netvanta Usb Wwan Nim (P/N 1702803F1)

    Series and NetVanta 3400 Series. For specific connection and configuration instructions, refer to the NetVanta USB WWAN NIM Quick Start Guide shipped with the NIM or online at http://kb.adtran.com. See Table A-13 on page 89 for the USB WWAN connector pinouts.
  • Page 58: Dial Backup Interface Modules

    Relative Humidity: Up to 95 percent, noncondensing Physical • Dimensions: 2.5-inch W x 3.75-inch D The Analog Modem DIM can be used in two different modes: 1. Backup interface for a primary connection. 2. CONSOLE port for remote dial-in access. Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 59: Netvanta Isdn Bri Dim (P/N 1200865L1)

    IC CS-03 • UL/CUL 60950-1 Environmental • Operating Temperature: 0°C to 50°C • Storage Temperature: -20°C to 70°C • Relative Humidity: Up to 95 percent, noncondensing Physical • Dimensions: 2.5-inch W x 3.75-inch D 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 60: Netvanta Isdn S/T Dim (P/N 1200875L1)

    IEC 60950-1 • AS/NZS 60950-1 Environmental • Operating Temperature: 0°C to 50°C • Storage Temperature: -20°C to 70°C • Relative Humidity: Up to 95 percent, noncondensing Physical • Dimensions: 2.5-inch W x 3.75-inch D Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 61: Unit Installation

    UL/IEC 60950-1. • PoE cables are intended for intrabuilding use only. Connecting an ADTRAN PoE unit directly to PoE cables that run outside the building in which the unit is housed will void the user's warranty and could create a fire or shock hazard.
  • Page 62: Mounting Options

    • Reliable grounding of rack-mounted equipment should be maintained. Particular attention should be given to supply connections other than direct connections to the branch circuit (e.g., use of power strips). Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 63: Wall Mounting Netvanta 3200/3300/3400 Series

    Do not attach the power cord to the building surface or run it through walls, ceilings, floors, or openings in the building structure. • The socket-outlet must be installed near the equipment and must be easily accessible. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 64: Figure 29. Wall Mounting The Netvanta 3200

    Slide the keyed insets on the bottom of the unit’s chassis securely onto the screws. Proceed to the steps given in Supplying Power to the Unit on page Figure 29. Wall Mounting the NetVanta 3200 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 65: Figure 30. Repositioning The Mounting Bracket For Wall Mounting The Netvanta 3205/3305

    See Figure Proceed to the steps given in Supplying Power to the Unit on page Figure 30. Repositioning the Mounting Bracket for Wall Mounting the NetVanta 3205/3305 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 66: Figure 31. Wall Mounting The Netvanta 3430/Netvanta 3448

    Once the unit is hanging, screw the wallmount bracket securely to the wall using a #6 PAN head screw (1.5-inch or greater in length). Proceed to the steps given in Supplying Power to the Unit on page Figure 31. Wall Mounting the NetVanta 3430/NetVanta 3448 Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 67: Wall Mounting The Netvanta Poe Power Supply

    The NetVanta PoE Power Supply can be wall mounted. This power supply is only available with the Octal PoE Upgrade bundle for the NetVanta 3448 and the NetVanta 3458, which include the power supply and the Octal PoE module.Follow these steps to wallmount the NetVanta PoE Power Supply: 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 68: Figure 33. Wall Mounting The Netvanta Poe Power Supply

    UL 60950-1. Under full load, the NetVanta PoE power supply may be hot to the touch. Figure 33. Wall Mounting the NetVanta PoE Power Supply Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 69: Supplying Power To The Unit

    Release the sheath so that it covers the metal connector. This ensures that the connector will not become disengaged during use. Figure 34. NetVanta 3200 Power Connector 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 70: Powering The Netvanta 3205 (Ac), Netvanta 3305, Netvanta 3430, Netvanta

    The NetVanta PoE Power Supply should be installed in a restricted access location as described in UL 60950-1. Under full load, the NetVanta PoE Power Supply may be hot to the touch. Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 71: Powering The Netvanta 3205 (Ac), Netvanta 3305, Netvanta 3430, Netvanta 3448, Netvanta 3450, And Netvanta 3458

    This interface is designed for use as an intra-building interface only. The addition of primary protectors is not sufficient protection in order to connect this interface metallically to OSP wiring. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 72: Figure 35. Netvanta 3205 Dc Power Connection

    Ground Ground Ground 24/-48V , 1A 24/-48V , 1A +24 VDC -48 VDC AC In AC In Power Power Supply Supply To Earth To Earth Ground Ground Figure 35. NetVanta 3205 DC Power Connection Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 73 Connect the negative terminal of the -48 VDC power source to the negative terminal of the NetVanta 3205 DC power connector. Connect the ground terminal of the NetVanta 3205 DC power connector to Earth ground. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 74: Installing Dial Backup And Network Interface Modules

    Secure the DIM to the NIM using the screws and standoff posts supplied. See Figure Slide the NIM with the DIM attached into the NetVanta chassis, continuing with the normal NIM installation (refer to Instructions for Installing the NIMs below). Figure 36. Installing DIMs Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 75: Figure 37. Nim And Dim Installation

    Slide the option module into the option slot until the module is firmly seated against the chassis. Secure the pins at both edges of the module. Connect the cables to the associated device(s). Restore power to the unit. WAN-T1 DSX-1 Figure 37. NIM and DIM Installation 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 76: Using A Usb Cellular Modem With The Netvanta Usb Wwan Nim

    Refer to the quick start guide that shipped with the NetVanta USB WWAN NIM for instructions on obtaining a cellular account and activating your USB cellular modem. An optional USB Locking Mechanism is available from ADTRAN (P/N 1700643G1) to lock the USB to the NetVanta USB WWAN NIM.
  • Page 77: Installing The Netvanta Vpn Accelerator Card (Included In P/N 4200368L1)

    Gently slide the accelerator card into the PCI slot as shown. The card is keyed to fit into the slot only one way. To avoid damaging the card pins, do not use excessive force. Replace the unit cover, screws, and mounting brackets. Restore power to the unit. Figure 38. NetVanta VPN Accelerator Card Installation 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 78: Installing Sodimm For Expandable Memory

    Follow these instructions to install a SODIMM module. • SODIMMs are intended to be installed only by qualified service personnel. • There are three types of SODIMM memory modules used by ADTRAN: 200-pin DDR1, 200-pin DDR2, and 144-pin DDR2. Although these modules look very similar, they are not interchangeable.
  • Page 79: Figure 39. Sodimm Installation - Keyed Slots

    NetVanta 3200/3300/3400 Series Unit Installation Figure 39. SODIMM Installation – Keyed Slots Figure 40. SODIMM Installation – Applying Pressure Figure 41. SODIMM Installation – Rotating the Module Downward 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 80: Installing A Compactflash Card

    Unit Installation NetVanta 3200/3300/3400 Series Installing a CompactFlash Card slot supports only ADTRAN-provided 1 GB CompactFlash cards (P/N 1200819E1). CompactFlash Follow these instructions when installing a card. The CompactFlash card is hot-swappable and can be inserted or removed while power is applied to the unit.
  • Page 81 Place modules in antistatic packing material when transporting or storing. When working on modules, always place them on an approved antistatic mat that is electrically grounded. The NetVanta Octal PoE Upgrade Module is intended to be installed only by qualified service personnel. 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 82: Installing The Octal Poe Upgrade Module

    ADTRAN Support Community. For details on the command line interface (CLI), refer to the AOS Command Reference Guide. All other related documents are also available online at http://supportforums.adtran.com. Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 83: Table A-1. 10/100Base-T Ethernet Port Pinouts

    Data Carrier Detect (output) Receive Data (output) Transmit Data (input) Data Terminal Ready (input) Signal Ground Data Set Ready (output) Tied to pin 1 — Unused Clear to Send (output) Tied to pin 1 — Unused 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 84: Table A-3. Console Port (Dce) Pinouts For Netvanta 3305

    Name +24 VDC Source -48 VDC Source +24 VDC Ground (GND) Ground (GND) -48 VDC Table A-5. ADSL Connector Pinouts Name Description 1, 2 — Unused ADSL Tip ADSL Ring 5, 6 — Unused Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 85: Appendix A. Connector Pin Definitions

    Unused Table A-8. WAN-E1 Connector Pinouts Name Description Receive data from the network–Ring 1 Receive data from the network–Tip 1 — Unused Transmit data toward the network–Ring Transmit data toward the network–Tip — Unused 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 86: Table A-9. Dsx-1 Connector Pinouts

    Unused Receive data from the DTE–Ring 1 Receive data from the DTE–Tip 1 — Unused Table A-11. WAN-SHDSL Connector Pinouts Name Description Loop 2–Tip Loop 2–Ring — Unused Loop 1–Tip Loop 1–Ring — Unused Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 87: Table A-12. Wan-Adsl Connector Pinouts

    Description 1, 2 — Unused ADSL Ring ADSL Tip 5, 6 — Unused Table A-13. USB WWAN Connector Pinouts Name Description Vbus Provides 5 VDC power up to 1000 mA Data Data Ground Ground 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 88: Table A-14. Serial To Cable Connector Pinouts

    Table A-14. Serial to Cable Connector Pinouts Serial V.35 X.21 EIA 530 Name TD_A ETC_A TCLK_A RCLK_A RD_A DCD_A DTR_A RTS_A RTS_B (V.11 only) CTS_B (V.11 only) CTS_A DSR_A TM_A TD_B ETC_B TCLK_B RCLK_B RD_B 19-25 Unused Ground Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...
  • Page 89: Table A-15. Analog Modem And Isdn Bri Dbu Connector Pinouts

    Description — Unused Network–Ring Network–Tip — Unused Table A-16. ISDN S/T DBU Connector Pinouts Name Description 1, 2 — Unused Network Receive–Ring 1 Network Transmit–Ring Network Transmit–Tip Network Transmit–Tip 1 7, 8 — Unused 61200860L1-34AB Copyright © 2012 ADTRAN, Inc.
  • Page 90 Appendix A. Connector Pin Definitions NetVanta 3200/3300/3400 Series Copyright © 2012 ADTRAN, Inc. 61200860L1-34AB...

Table of Contents