5.3

Connecting two or more applications with a DC link system

to one Energy storage solution

Only one application has a brake resistor
Connect the Energy storage solution to this application.
Connect the brake resistor line to this application.
Several applications have a brake resistor and it is certain
that all applications always brake at the same time
Connect the Energy storage solution to any application.
Connect the brake resistor line to the same application.
Several applications have a brake resistor and it is not certain
that all applications always brake at the same time
(only for Energy storage solutions with a fixed setting for the working voltage
on the DC link)
Connect the Energy storage solution to any application.
Do not connect the brake resistor line (fixed default setting).
5 Commissioning