System Cooling

The SC101S includes one 4-cm fan. The chassis also supports an additional optional 4-cm
fan.
Replacing the System Fan
1. Power down the system as described in section 3-1 and remove the AC power cord and
the chassis cover.
2. Remove the failed fan power cable from motherboard.
3. Remove the screws securing the fan to the chassis wall and set these aside for later
use.
4. Lift the fan out of the chassis.
5. Align the replacement fan with the holes in the wall of the chassis.
6. Secure the fan to the chassis wall using the screws previously set aside.
7. Reconnect the fan cable to motherboard.
8. Reinstall the chassis top cover, reconnect the AC power cord and power up the system.
Figure 2-5. System Fan