Kessel Aqualift Basic Mono Installation And Operating Instructions Manual page 29

Hide thumbs Also See for Aqualift Basic Mono:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 22
4.2
Electrical connection
DANGER
Danger through incorrectly dimensioned connection
cables.
The system is intended exclusively for operation
with the connection pipes provided (or equivalent).
In case of doubt, contact the manufacturer/supplier.
Lay the connection cable securely (e.g. conduit pipe) from
the system tank to the control unit. Ensure that there is
adequate cable length for the maintenance of the electri-
cal components.
Attach ferrules (length 8 mm) to the cable ends.
Unscrew and remove housing cover.
016-207_01
Feed connection cable through suitable cable pass-
through.
Fasten connection cable to the terminal strips in accor-
dance with connection diagram.
To do so, use a suitable screwdriver to hold down the
respective cable clamp against the spring pressure until
the cable end has been inserted.
Fasten strain relief for all connection cables - tightening
torque 0.5 Nm.
Fit battery connector onto the battery.
Route the battery cable such that the LEDs are not cov-
ered or trapped.
Fit the housing cover and fasten in place - screw tighten-
ing torque 1.2 Nm.