Kessel Aqualift Mono Manual
Hide thumbs Also See for Aqualift Mono:
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

Einbau- und Betriebsanleitung
Einbau- und Betriebsanleitung
DE
DE
........................................................................................................................ 2
........................................................................................................................ 2
EN
EN
...................................................................................................................... 20
...................................................................................................................... 20
CN
CN
...................................................................................................................... 38
...................................................................................................................... 38
2021/06
Schaltgerät Aqualift
Schaltgerät Aqualift
230V Mono/Duo
230V Mono/Duo
010-910_04

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for Kessel Aqualift Mono

  • Page 1 Schaltgerät Aqualift Schaltgerät Aqualift 230V Mono/Duo 230V Mono/Duo Einbau- und Betriebsanleitung Einbau- und Betriebsanleitung ........................2 ........................2 ........................20 ........................20 ........................38 ........................38 2021/06 010-910_04...
  • Page 2: Table Of Contents

    Liebe Kundin, lieber Kunde, als Premiumhersteller von innovativen Produkten für die Entwässerungstechnik bietet KESSEL ganzheitliche Systemlösun- gen und kundenorientierten Service. Dabei stellen wir höchste Qualitätsstandards und setzen konsequent auf Nachhaltig- keit - nicht nur bei der Herstellung unserer Produkte, sondern auch im Hinblick auf deren langfristigen Betrieb setzen wir uns dafür ein, dass Sie und Ihr Eigentum dauerhaft geschützt sind.
  • Page 3: Hinweise Zu Dieser Anleitung

    Hinweise zu dieser Anleitung Folgende Darstellungskonventionen erleichtern die Orientierung: Darstellung Erläuterung siehe Abbildung 1 Positionsnummer 5 von nebenstehender Abbildung Handlungsschritt in Abbildung Prüfen, ob Handbetrieb aktiviert wurde. Handlungsvoraussetzung OK betätigen. Handlungsschritt Anlage ist betriebsbereit. Handlungsergebnis Querverweis auf Kapitel 2 siehe "Sicherheit", Seite 4 Fettdruck besonders wichtige oder sicherheitsrelevante Information Variante oder Zusatzinformation (z.
  • Page 4: Sicherheit

    Spannungsführende Teile! Das Gehäuse des Schaltgeräts darf nur von einer Elektrofachkraft geöffnet werden! Die Tätigkeiten am Schaltgerät sind auf: den Tausch der Batterien, das Anschließen nach Einbauanleitung und Anschlussplan beschränkt. Alle darüber hinausgehenden Arbeiten dürfen lediglich durch den KESSEL-Kundendienst oder einen Servicepartner der KESSEL AG durchgeführt werden. WARNUNG Spannungsführende Teile Bei Tätigkeiten an elektrischen Leitungen und Anschlüssen Folgendes beachten.
  • Page 5 Produktbeschreibung Display Typenschild Kabeldurchführungen, Anschlüsse Netzanschlussleitung Power-LED Taste Pumpe 1 Alarm-LED LED Pumpe 1 Taste Alarm quittieren Taste Pumpe 2 LED Niveauüberschreitung LED Pumpe 2 Pfeiltasten, OK, ESC 010-910_04 5 / 56...
  • Page 6 Bestimmungsgemäße Verwendung Das Schaltgerät stellt die Steuerung einer Hebeanlage oder Pumpstation für Abwasser dar. Als Niveauerfassung können Drucksensoren, Schwimmerschalter oder Sonden verwendet werden. Ist das Schaltniveau erreicht, wird das Abpumpen akti- viert. Ist das Niveau entsprechend abgesunken, wird das Abpumpen selbsttätig beendet. Alle nicht vom Hersteller ausdrücklich und schriftlich autorisierten: Um- oder Anbauten Verwendungen von nicht originalen Ersatzteilen...
  • Page 7: Technische Daten

    Technische Daten Ausführung Mono Maximale Leistung (kW) am 1,6 KW 2x 1,6 KW Schaltausgang (bei cos φ = 1) Nennstrombereich je nach Pumpe Strombereich 1-10 A 2x 1-10 A Gewicht 1,2 kg 1,4 kg Abmessungen (LxBxT), mm 210x200x75 295x200x75 Betriebsspannung 230V / 50Hz Leistung, Standby 3,5 W...
  • Page 8: Montage

    Drehmoment beachten! vormontierte oder beigelegte Kabelverschraubungen zur Kabeldurchführung (z. B. M16). Die Aderenden müssen hier bis zu den Anschlussklemmen auf der Platine durch- geführt werden. KESSEL 230V Schaltgeräte werden generell mit stecker- fertig vormontierter Netzleitung (Schukostecker) ausgelie- fert. Leitungsart A Kabelverschraubung Netz B Stecker (groß)
  • Page 9 Pumpe(n) anschließen WARNUNG Gefahr durch elektrischen Strom bei unbefugtem Demontieren eines Steckers während des Betriebs (z.B. durch Kinder). Die Befestigungsmutter des Steckers muss so fest angezogen werden, dass Kinder sie nicht entfernen können. Kabel mit Stecker passend kürzen und/oder verlängern. Zur Verlängerung ausschließlich passendes Kabelverlän- gerungsset (Art.Nr.
  • Page 10 Standardkonfiguration von Sonden Die Standardkonfiguration von KESSEL-Hebeanlagen ist ein Drucksensor (Tauchrohr oder Tauchglocke). Ein optischer Sensor als Alarmsonde liegt entweder bei oder kann auf den bereits vormontierten Anschluss montiert werden. Drucksensor Soll ein Drucksensor zur Ermittlung des Füllstandes verwen- det werden, diesen wie folgt anschließen.
  • Page 11 Die von der Standardkonfiguration abweichenden Sensoren können für besondere Anwendungen (z. B. beengte Platz- verhältnisse oder besondere Medien) verwendet werden. In KESSEL-Anlagen dürfen nur Sensoren montiert wer- den, die von KESSEL zur Nachrüstung ausgewiesen wur- den. Außenanschluss tauschen/nachrüsten VORSICHT Das Anschließen von elektrischen Leitungen inner- halb des Schaltgerätes ist ausschließlich Elektrof-...
  • Page 12 Schwimmerschalter Mono/Duo Prüfen, ob eine Mono oder Duo-Anlage vorliegt. Niveau für EIN 1, ggf. EIN 2 (Duo) und AUS definieren. KESSEL empfiehlt grundsätzlich zu den oben genannten ein Alarmniveau auszuführen. Fällt ein Schwimmerschalter aus, können die Schwim- merschalter übergangsweise auch so getauscht wer- den, dass auf das AUS-Niveau verzichtet wird.
  • Page 13 USB-Anschluss herausführen Damit der USB-Anschluss auf der Platine ohne ein Öffnen des Gehäuses zugänglich wird, kann eine USB-Gehäusebuchse mit Kabel und Stecker zum Einbau in das Gehäuse des Schaltgeräts bei KESSEL bestellt werden (Art.-Nr. 28785). Diverses Zubehör - Schaltgeräte Fernsignalgeber Art.--Nr. 20162 Warnleuchte Art.-Nr.
  • Page 14: Inbetriebnahme

    Inbetriebnahme Folgende Zusatzfunktionen führt das Schaltgerät selbsttätig aus: Überprüfung der Batteriespannung Das Schaltgerät prüft 2x täglich die Batteriespannung und meldet einen Batteriefehler (Potentialfreier Kontakt "Störung"), wenn die Spannung ein bestimmtes Niveau unterschreitet. Am Schaltgerät erscheinen alle 20 Sekunden optische und akkustische Warnsignale.
  • Page 15 die Alarm-LED blinkt rot, eine Fehlermeldung erscheint im Display, ein akustischer Signalton ertönt. Taste Alarm quitteren 3 Sekunden betätigen. Ist die Fehlerursache behoben, verstummt der akustische Signalton und die LED hört auf zu blinken. Ein kurzes Betätigen der Taste Alarm schaltet den Alarmton aus, erhält jedoch die Fehlermeldung im Display und als Blinkmuster.
  • Page 16 Menütexte Aqualift 230V Systeminfo Informationen Betriebsstunden 1.1.1 Gesamtlaufzeit 0 - 999,999,9 1.1.2 Laufzeit Pumpe 1 0 - 999,999,9 1.1.3 Schaltspiele Pumpe 1 0 - 999,999,9 1.1.4 Netzausfall 0 - 999,999,9 1.1.5 Energieverbrauch 0,0 - 999,999,9 1.1.6 Laufzeit Pumpe 2 0 - 999,999,9 1.1.7 Schaltspiele Pumpe 2 0 - 999,999,9...
  • Page 17 2.6.3 Privat 12 Monate 2.6.4 Manuelle Wartung 2.6.5 kein Wartungsintervall Kalibrierung Einstellungen Parameter 3.1.1 Einschaltverzögerung 0 - 999 3.1.2 Nachlaufzeit 0 - 99 3.1.3 Max. Schaltspiele 3.1.4 Max. Strom 3.1.5 Min. Strom 3.1.6 Grenzlaufzahl 3.1.7 Grenzlaufzeit 3.1.8 Lufteinperlung-Offset 3.1.9 Höhe Stauglocke 3.1.10 SDS Selbstdiagnosesystem 3.1.11...
  • Page 18 3.4.17 Hebeanlage S 100l 3.4.18 Hebeanlage S 200l 3.4.19 Sonder-Hebeanlage 3.4.20 Sonder-Pumpstation Sensorkonfiguration 3.5.1 Drucksensor+Optische-Sonde 3.5.2 Drucksensor+Leitfähig- keit-Sonde 3.5.3 Drucksensor+Alarmschwimmer 3.5.4 Drucksensor+Lufteinperlung 3.5.5 Drucksensor+Lufteinperlung+ Alarmschwimmer 3.5.6 Drucksensor+Lufteinperlung+ optische Sonde 3.5.7 Schwimmer 3.5.8 Schwimmer ohne Aus-Niveau 3.5.9 Pegelsonde 3.5.10 Pegelsonde + Alarmschwimmer 3.5.11 Leitfähtigkeit-Sonde 3.5.12...
  • Page 19: Wartung

    Wartung Wartungstermin einstellen Der Wartungstermin wird über das Menü 2, Punkt 2.4 eingestellt. Folgen Sie dem Bildschirmdialog (zur Bedienung siehe "Abb. 3: Navigieren im Menü", Seite 14 ). Selbstdiagnosesystem (SDS) Das Selbstdiagnosesystem prüft automatisch (Intervall einstellbar) nachstehend beschriebene Anlagenfunktionen. Diese Einstellungen werden über das Menü...
  • Page 20 Dear Customer, As a premium manufacturer of innovative products for draining technology, KESSEL offers integrated system solutions and customer-oriented service. In doing so, we set the highest quality standards and focus firmly on sustainability - not only with the manufacturing of our products, but also with regard to their long-term operation and we strive to ensure that you and your property are protected over the long term.
  • Page 21: Notes On This Manual

    Notes on this manual The following conventions make it easier to navigate the manual: Symbol Explanation See Figure 1 Position number 5 from the adjacent figure Action step in figure Check whether manual operation has been Prerequisite for action activated. Press OK.
  • Page 22: Safety

    Work on the control unit is restricted to: replacing the batteries, connection in accordance with the installation instructions and connection diagram. All work extending beyond this may only be carried out by the KESSEL customer service or a service partner of KESSEL AG WARNING Live parts Heed the following points when working on electrical cables and connections.
  • Page 23 Product description Display Type plate Cable passages, connections Mains cable Power-LED Button, Pump 1 Alarm LED LED Pump 1 Button, acknowledge alarm Button, Pump 2 LED level exceedance LED Pump 2 Arrow buttons, OK, ESC 010-910 23 / 56...
  • Page 24 Intended use The control unit represents the control of a lifting station or a pumping station for wastewater. Pressure sensors, float switches or probes can be used for level measurement. When the switching level has been reached, the pump-off function is activated.
  • Page 25: Technical Data

    Technical data Version Mono Maximum power (kW) at the 1.6 kW 2x 1.6 kW switch output (if cos φ = 1) Nominal current range depending on the pump Current range 1-10 A 2x 1-10 A Weight 1.2 kg 1.4 kg Dimensions (LxWxD), mm 210x200x75 295x200x75...
  • Page 26: Installation

    Hang the control unit on the fastening screws and press downwards gently. (1) Sensor variants KESSEL control units are preconfigured for standard assign- ments, but also allow numerous accessories to be retrofitted and/or the installation of, for example, application-specific sensor configurations or communication interfaces.
  • Page 27 Connecting the pump(s) WARNUNG Electric shock hazard caused by unauthorised dis- mantling of a connector during operation (e.g. by children). The mounting nut of the connector must be tight- ened sufficiently so that it cannot be removed by children. Shorten and/or lengthen cable with plug to fit. To lengthen, only use the matching cable extension set (art.no.
  • Page 28 Standard configuration of probes The standard configuration of KESSEL lifting stations is a pressure sensor (immersion pipe or submersible pressure switch). An optical sensor for use as an alarm probe is either enclosed or can be mounted on the already preassembled connection.
  • Page 29 Wire colour Name on PCB Terminal colour (-)Black blue not occupied Probe white (+)Red black Use KESSEL junction box (art. no. 28799) to lengthen the connection cable of the level sensor. 010-910 29 / 56...
  • Page 30 Check whether the system is a Mono or a Duo system. Define level for ON 1, if applicable, ON 2 (Duo) and OFF. KESSEL recommends providing an alarm level for the items named above. If a float switch fails, the float switches can be swapped temporarily so that the OFF level does not have to be used.
  • Page 31 To ensure that the USB connection on the printed board can be accessed without opening the housing, a USB housing socket with cable and connector for installation in the housing of the control unit can be ordered from KESSEL (art. no.
  • Page 32: Commissioning

    Commissioning The control unit performs the following additional functions automatically: Checking the battery voltage The control unit checks the battery voltage 2x daily and signals a battery error (potential-free contact “fault”) if the voltage falls below a certain level. Optical and acoustic warning signals appear on the control unit every 20 seconds. SDS self-check The control unit has an automatic self-check, which performs a functional check of the connected movable components automatically.
  • Page 33 Acknowledge alarm The control unit displays (alarm) messages as follows: the alarm LED flashes red, an error message appears in the display, an acoustic signal sounds. Press the Alarm button for 3 seconds to acknowledge. If the cause of the error has been corrected, the acoustic signal falls silent and the LED stops flashing.
  • Page 34 1.6. Parameter 1.6.1 On delay 1.6.2 Post run time 0-99 PW: 1000 1.6.3 Total run occur 1.6.4 Max. current 0.5 - 2.5 1.6.5 Min. current 0.5 - 2.5 1.6.6 Max. run occur 1.6.7 Max. run time 1.6.8 Air compressor offset 1.6.9 Sensor height 1.6.10...
  • Page 35 3.1.14 Alarm level 0 - 5000 3.1.15 ON 2 - level 0 - 5000 3.1.16 OFF 2 - level 0 - 5000 Profile memory 3.2.1 Load parameters 3.2.2 Save parameters Date/Time Type Aqualift 3.4.1 Lifting station F Compact 3.4.2 Lifting station F 3.4.3 Lifting station F XL 200 l 3.4.4...
  • Page 36 3.6. Communication 3.6.1 Station name 3.6.2 Own number 3.6.3 Modem type 3.6.4 3.6.5 SMS centre 3.6.6 SMS destination 1 3.6.7 SMS destination 2 3.6.8 SMS destination 3 3.6.9 Status 3.7. Language 3.10.1 Deutsch 3.10.2 English 3.10.3 Français 3.10.4 Italiano 3.10.5 Nederlands 3.10.6 Polski...
  • Page 37: Maintenance

    Maintenance Setting maintenance date The maintenance date is set via Menu 2, Item 2.4. Follow the screen dialogue (for details of operation, seesee "Fig. 3: Navi- gating in the menu", page 32 ). Self-diagnosis system (SDS) The self-diagnosis system checks the described system functions automatically (interval adjustable). These settings are made via Menu 3.1.9 (see "Menu texts Aqualift 230V", page 33).
  • Page 38 亲爱的客户: 作为创新排水技术产品的优质制造商,科赛尔提供一体化系统解决方案和客户至上的服务。在此过程中,我们树立了最高的质 量标准,坚定地着眼于可持续发展—不仅对于制造产品,还包括产品的长期运行,我们努力确保您和您的财产得到长期保护。 科赛尔股份公司 Bahnhofstraße 31 85101 Lenting, Germany 我们在当地具有资质的服务合作伙伴将十分乐意帮助您解决任何技术问题。 您可以通过以下网址找到可联系的合作伙伴: www.kessel.de/kundendienst 必要时,我们的工厂客户服务团队在DACH区域可以提供调试、保养维护或一般检验等服务支持;其他国 家/地区的客户如有要求,服务团队也会及时提供支持。 有关处理与订购的信息,请访问: http://www.kessel.de/service/kundenservice.html 目录 本手册说明......................................... 安全..........................................技术数据........................................安装..........................................调试..........................................维护..........................................38 / 56 010-910_02...
  • Page 39: 本手册说明

    本手册说明 了解以下惯例有助于理解本手册: 标志 解释 见插图1 旁边插图中的位置编号5 插图中的操作步骤 检查手动控制是否已激活 操作的前提 按“确定” 操作步骤 系统准备运行 操作结果 参阅 "安全", 页 40 交叉参考第2章 粗体 尤为重要的或与安全相关的信息 斜体 配置或附加信息(如:仅适用于ATEX配置) 必须格外注意的技术信息或说明 使用下列符号: 图标 含义 设备间独立 遵守使用说明 警告,有电 WEEE标准,产品受ROHS指南操作管理 使用前接地 警告有人员危险,忽视这一警告可能导致严重伤害或死亡 警告 警告有人员和材料危险,忽视这一警告可能会严重伤害和财产损失 注意 010-910_02 39 / 56...
  • Page 40 安全 一般安全须知 注意 断开系统的电源! 确保在工作期间断开电气组件的电源。 警告 带电部件!电控箱的外壳只能由有资质的电气技术人员打开! 用户对电控箱可执行的工作仅限于: 更换电池, 按照安装说明和连接图进行连接。 此范围以外的所有操作只能由KESSEL客服或KESSEL AG的服务合作伙伴来执行 警告 带电部件 处理电缆和连接时请注意以下几点: 有关电气安全的国家/地区法规适用于所有连接和安装作业。 此系统必须经由剩余漏电保护器(RCD)来供电,并且剩余电流不得超过30 mA。 操作和设备维护保养说明应放在产品旁边以便查阅。 人员/资格 相关的操作安全规定与危险物质条例或国家/地区的同等法规皆适用于系统的运行。 系统操作员必须: 准备风险评估 识别并划分相应危险区 参加安全培训 防止未经授权使用系统 人员 允许对KESSEL系统实施的措施 运营公司 外观检查,检查 专家,(熟悉、理解操作说明) 功能检查,电控箱配置 VDE 0105电气专员(遵循电气安 电气安装 全法规或国家/地区的同等法规) 1) 执行操作与装配工作的人员必须年满18岁。 40 / 56...
  • Page 41 产品描述 显示屏 铭牌 线缆通道,连接 电源电缆 电源LED 按钮,泵1 报警LED LED泵1 按钮,确认报警 按钮,泵2 LED液位超标 LED泵2 箭头按钮,OK,ESC 010-910_02 41 / 56...
  • Page 42 预期用途 电控箱的作用是控制污水提升器或提升泵站。在进行液位测量时,可以使用压力传感器、浮球开关或探头。液位达到启动液位 时,泵出功能激活。液位下降后,泵关闭功能自动结束。 所有: 修改或附件 使用非原装备件 由未经制造商授权的公司或人员进行的维修 若未经制造商的明确书面许可,可能会导致保修失效。 配置户外用控制柜的注意事项 小心 超出工作温度可能导致电控箱故障。 考虑户外用控制柜安装区域的温度 评估安装现场的日照情况。 考虑现场环境条件。 下表简要说明了各个环境下需要测量的数据。 预计每天强日照时间为8小时或以上并且/或者有高温环境 需要安装空调机组(根据要求提供)。 空气聚集 预计日照强度不定期增强 需要安装具有温度检测功能的标准风扇以保证内部通风。 控制柜内部温度达到40°C时应开始通风。 安装位置位于持续阴暗区域和/或温度小幅度波动的环 不需要测量。 境。 42 / 56 010-910_02...
  • Page 43: 技术数据

    技术数据 版本 单泵 双泵 开关输出的最大功率(kW)(如果cos φ = 1) 1.6 kW 2x 1.6 kW 额定电流范围 取决于泵 电流范围 1-10 A 2x 1-10 A 重量 1.2 kg 1.4 kg 外形尺寸(LxWxD), mm 210x200x75 295x200x75 工作电压 230V / 50Hz 待机功率 3.5 W 无源干接点 最大42 V DC / 0.5 A 电池规格...
  • Page 44 此,请确保螺丝头与紧固表面之间的距离(A)大约是3至4 mm。 如果有计划,请将USB连接引至外壳外面,"更多可能的连 接" . 将电控箱挂在紧固螺丝上,然后轻轻向下按。(1) 传感器多样化 KESSEL电控箱已提前配置标准任务,但也允许改装和/或安装 许多附件,比如特定应用的传感器配置或通讯接口等。 电控箱的连接类型 带插头设备,电缆已预组装完毕(例如Schuko接地安全插 头) 电控箱底部的外部连接已预组装完毕(例如压力软管进 口、接头)。如果未安装隔离垫圈,应特别注意要符合规 定的扭矩! 线缆通道的电缆格兰头已预组装或封闭(例如M16)。导 线端头必须经由此处连接到印刷电路板上的连接端子。 一般情况下,KESSEL 230V电控箱在交付时带插头设备电 源电缆已预组装完毕(Schuko接地安全插头),可以直接 插入。 类型 导体类型 A 电缆格兰头 电源 B 接头(大) 泵1 C 接头(大)* 泵2* D 接头(小) 报警探头 E 压力软管进口 沉入式压力开关(管路) F 带盲塞的开口...
  • Page 45 连接泵 WARNUNG 在运行过程中,若未经授权(例如儿童)擅自拆卸接 头,可能导致触电危险。 接头的安装螺母必须充分拧紧,以防止儿童拆 卸。 在安装时,利用插头来缩短和/或加长线缆。加长时,只可 使用匹配的电缆延长组件(编号80889)。缩短时,请按 照下述步骤进行操作: 将电缆布放到连接处,额外预留5 cm。 使用组合钳剪断。剥掉大约3 cm电缆护套。 从电缆剪断处取下螺母,然后推入到裸露的导线上。 将导线弯折到侧面的凹槽中, 然后平齐剪断。 剩余安装不需要任何工具。 卸下螺母(接头)和保护帽。 使电缆箭头对准箭头,装上线缆。 拧紧接头,使隔离垫圈平齐连接。如果未安装隔离垫圈, 请注意3 Nm的紧固扭矩。 若扭矩正确,则在未安装隔离垫圈的情况下,螺母与六角 体之间的间隙为3-4 mm。 010-910_02 45 / 56...
  • Page 46 探头的标准配置 KESSEL污水提升器的标准配置是压力传感器(压力开关管或 沉入式压力开关)。用作报警探头的光学传感器或者是封闭 的,或者安装在已预组装的连接上。 压力传感器 如果压力传感器用于液位检测,则必须按下述方式进行连 接。 借助螺旋电缆牵引器,将压力软管穿过电缆穿线管;为 此,将带有密封帽的软管端头固定在螺旋线缆牵引器上。 将带有密封帽的压力软管端头剪断,以精准安装。 推入蓝色释放环,使其保持按压状态。 如果不可行, 则将压力软管推到压力管路连接的连接接头上。 将压力软管的端头推入接头,直至其停止。 拧紧夹紧螺 母。 松开释放环。 压力软管完成密封连接。 轻轻拉动压力软管,以检查连接是否牢固。 压力软管在布放时应使其不断抬升。 如果长度超过10 m或压力软管出现反向管路坡度,请使用 压缩机组进行空气鼓泡(产品编号28048)。 光学探头 将探头电缆布放至报警探头。 取下保护帽。 检查是否存在间隔环。 将插头推到连接处(箭头朝上)。 不提供间隔环。用扳手(15mm)拧紧塞子,观察对面所 示的间隙尺寸或扭矩。 存在间隔环。用手将插头拧紧,使其平齐。 46 / 56 010-910_02...
  • Page 47 单个传感器配置 从标准配置派生的传感器可用于特定应用(例如,受限空间 或特定介质)。 只有KESSEL指定可改装的传感器可以安装在KESSEL系统 中。 更换/改装外部连接 小心 只有具备资质的电气技术人员(依照国家/地区有关 电气安全的规定)可以连接电控箱内部的电缆。 安装替代传感器配置时,可能需要更换或改装电控箱底部 的外部连接。 在推入一字螺丝刀的同时牵拉导线,将其从接线板中拉 出。 使用22号扳手卸下端头配件。 推入电缆格兰头M16x1.5的螺纹,并用埋头螺母固定。 将电缆格兰头的螺母推到线缆端头上。将导线和电缆端头 穿过电缆格兰头的开口。 使用电控箱底部的盲塞来改装附加电缆格兰头。 液位传感器,单泵/双泵 将液位传感器的端头连接到探头接线板。单泵和双泵系统的 液位传感器的连接图是相同的。电控箱底部的外部连接可能 需要更换。 导线颜色 PCB上的名称 端子颜色 (-)黑色 蓝色 未占用 探头 白色 (+)红色 黑色 使用KESSEL接线盒(产品编号28799)加长液位传感器的 连接电缆。 010-910_02 47 / 56...
  • Page 48 浮球开关,单泵/双泵 检查系统是单泵还是双泵系统。 定义开启1、开启2(双泵)(如果适用)和关闭的液位。 KESSEL建议为上述项目提供报警液位。 如果浮球开关发生故障,可以临时代替浮球开关,从而 不必使用关闭液位。然后,通过泵的运行后时间在电控 箱中设置关闭。参见“设置”菜单“参数”选择中的 3.1.2 ##### | 。此程序不适合连续运行,因为泵应 避免空转。 位置 端子分配 图 1: 浮球开关双泵 报警液位 开启 2(仅限双泵) 开启1 关闭 图 2: 浮球开关单泵 电导探头 接线板最多可连接4个电导探头。 关闭 开 开 报警 启1 启2 接线板* 1 3触点探头,垂直 2 2触点探头,水平 3 2触点探头,垂直...
  • Page 49 更多可能的连接 TeleControl GSM调制解调器 按照相应的安装说明434-033中的描述来安装TeleControl调制解调器(产品编号28792)。 引出USB连接 为了确保在不打开外壳的情况下即可访问印刷电路板上的USB活接头,可以从KESSEL订购一个电控箱的内置USB插座盒(产 品编号28785,带有电缆和接头)。 各种附件 - 电控箱 外部声音报警器,产品编号20162 报警灯,产品编号97715 无源干接点,产品编号80072(插入印刷电路板) 无源干接点(可选附件) 如果需要,可以连接信号发生器或其他附件而作为无源干接点(42 V 0.5 A)。为此,可以使用下述端子: 警告(显示事件 - 例如报警液位已超出)-正常关闭- 故障(致命错误 - 例如在电气连接或安全系统中)-正常打开- 出现警告时,系统的运行可靠性通常不会立即面临风险。但是,应由有能力的人员立即对系统进行设备维护保养或检查。发生 故障时,系统功能可能会直接受影响,需要直接采取行动。联系技术服务人员或紧急服务。 选择附件部件(例如报警灯,产品编号97715),并接入到所需位置。按如下所述连接到电控箱: 按照连接图进行连接。 引出电控箱底部右侧的电缆。使用橡胶电缆格兰头替换现有的盲塞。 连接图,单泵/双泵 电源输入 压力传感器 泵1 单个传感器配置 泵2(仅限双泵) 外部声音报警器(产 品编号20162) 光学探头/液位传感器 无源干接点 010-910_02...
  • Page 50 调试 电控箱会自动执行以下附加功能: 检查电池电压 电控箱每天检查电池电压两次,当电压低于某个值时,会发出电池错误信号(无源干接点“故障”)。电控箱每20秒会出现 一次光学和声学警告信号。 SDS自动检查 电控箱具有自动检查功能,该功能可自动对已连接的移动部件进行功能检查。即便未出现倒灌问题,也会检查系统的准备状 态。 预设检测循环: 每28天(间隔时间可以为1-28天) 开启电源 打开外壳(逆时针)。 连接电池。 关闭外壳(顺时针)。 连接电源。 ##0 ####| 检查是否出现| 。(表示系统测试成功) 绿色LED表示待机状态(已做好运行准备)。 执行初始化 在初始化过程中,预计会有以下输入: |##| |##/##| |####| |########| 语言 # 按OK # 使用光标键选择语言,然后按OK确认。 |##/##| 菜单 显示出来。 日期/时间 # 设置日期和时间中闪烁的相应数字,然后按OK确认。 |####| 菜单 显示出来。 图...
  • Page 51 关闭电源 断开设备与电源的连接, 声音报警响起,报警LED闪烁。 关闭声音报警:按住报警按钮约 1秒钟,直到显示屏上的 报警符号被打叉为止。 按住报警按钮(至少5秒钟),直到显示屏和报警LED皆关 闭为止。 Aqualift电控箱电源关闭。 配置菜单概述 菜单概述 控制菜单分为四个菜单区域: 0 系统信息 - 选择的系统、配置的传感器、当前测量值;如果 有的话,事件或错误消息 1 信息- 显示运行数据(例如电压、当前测量值、日志或设置 参数) 2 维护 - 与设备维护保养有关的任务(例如,开/关泵、自诊 断、维护日期和间隔) 3 设置 - 设置开关液位、传感器和系统配置、调制解调器接口 配置、重置电控箱 菜单项编号 Aqualift 230V菜单文本 系统信息 信息 工作时长 1.1.1 总运行时长 0 - 999,999.9 1.1.2 运行时间泵1 0 - 999,999.9...
  • Page 52 1.6.14 报警液位 0 - 5000 1.6.15 开启2 - 液位 0 - 5000 1.6.16 关闭2 - 液位 0 - 5000 设备维护保养 手动操作 2.1.1 泵1 开启/关闭 2.1.2 无源干接点 2.1.3 外部声音报警 2.1.4 通信 2.1.5 泵2 自动运行 自动反馈系统(SDS) 2.3.1 自动反馈系统(SDS) 设备维护保养日期 2.4.1 上次设备维护保养日期 正常/错误 2.4.2 下次设备维护保养日期...
  • Page 53 3.4.7 泵站S XL KTP500/GTF600 3.4.8 泵站S KTP 500/GTF600 3.4.9 泵站S XL GTF 1200 3.4.10 泵站S GTF 1200 3.4.11 泵站F STZ 1000(无ATEX) 3.4.12 泵站F XL干式安装 3.4.13 泵站F XL GTF 1400,无ATEX 3.4.14 泵站F,无ATEX (Ama-Porter) 3.4.15 污水提升器,S Compact GTF500 3.4.16 污水提升器,S Compact GTF1200 3.4.17 污水提升器...
  • Page 54 维护 设置维护保养日期 维护保养日期通过菜单2的2.4条来设置。按照屏幕对话进行操作(详细操作请参见参阅 "图 3: 菜单导航", 页 50)。 自动反馈系统(SDS) 自动反馈系统(SDS)会自动检查所描述的系统功能(间隔时间可调)。这些设置通过菜单3.1.9来操作 (参阅 "Aqualift 230V菜 单文本", 页 51)。测试:泵1、泵2(双泵)、电池 如果发生错误,显示屏上将显示纯文本消息,并且报警LED会亮起。 校准压力传感器 正常老化过程会导致压力传感器出现液位偏差。压力传感器可以通过菜单项2.7进行自动校准。 请注意,校准应在10°C至30°C的室温下进行。 建议每年校准一次。 故障排除 显示文本 可能的原因 补救措施 电池错误 电池缺失、故障或剩余电压太小 检查电池连接,必要时更换电池。 设备维护保养日期(闪烁) - 设备的保养日期到了 - 执行设备维护保养 - 未输入设备维护保养日期 - 输入设备维护保养日期(见6.1) 欠电流1或2 - 未达到泵1或2的最低功耗 检查电缆,必要时进行更换;检查泵,必要...
  • Page 56 Registrieren Sie Ihr Produkt online, um von einer schnelleren Hilfe zu profitieren! http://www.kessel.de/service/produktregistrierung.html KESSEL AG, Bahnhofstr. 31, 85101 Lenting, Deutschland...