1.3. Safety instructions

DANGER
Escaping compressed gas
Risk of serious or even fatal injury from contact with escaping compressed gas or from unsecured plant
components.
DANGER
Mains voltage
Risk of electric shock with serious or fatal injuries if contact is made with non-insulated components
carrying mains voltage.
WARNING
Operating outside of limits
If the specified limits are exceeded, there is a risk of the device malfunctioning, potentially resulting in
injury and/or damage to property.
Skilled technical personnel
1
Skilled technical personnel use their professional qualifications and knowledge in the field of measuring, control and pneumatic
technology, and their knowledge of the applicable statutory regulations, guidelines and standards to independently foresee
potential dangers and are qualified to perform the tasks described. Special operating conditions (e.g. aggressive media) require
additional knowledge.
METPOINT
SF53
®
Depressurise the system before carrying out any assembly, installation or maintenance work. This
work must be performed by authorised skilled technical personnel
Use only pressure-resistant installation materials and suitable tools that are in proper working order.
Before pressurising the system, check all device parts and repair them as necessary. Open valves
slowly to prevent pressure blow-outs during operation.
Take action to prevent people or objects from being affected by condensate or escaping compressed
gas.
Prevent vibrations, oscillations and shocks from being transferred to system parts.
Observe all applicable regulations with respect to electrical installations (e.g. VDE 0100/IEC 60364).
Only execute installation and maintenance works when the system has been deenergised.
Electrical works may only be executed by authorised skilled technical personnel
Read off the permissible operating voltage on the rating plate and always comply with it.
Only utilise components for the electrical installation which have a current approval
and are labelled with a CE-Identification Marking.
A safely accessible circuit breaker (e.g. power plug or switch) must be provided close to the device for
disconnecting all current and/or power lines for the voltage supply.
The device must only be operated for the intended purpose and within the permissible limits
specified on the type plate and in the technical data.
Above 10 bar, use the high-pressure safety device for safe installation and removal.
The device is not designed for use with flammable gases.
Ensure strict observance of operating times and maintenance intervals.
Strictly adhere to the prescribed storage and transport conditions.
Prevent condensation on the sensor element and water droplets in the measurement air.