5. Commissioning

To commission the METPOINT
Following this, slowly pressurise the pipes.
6. Configuration and operation
After powering up, the METPOINT
The device menus are operated through two capacitive buttons:
>>UP<<
>>ENTER<<

6.1. Indicators used in operation

Gasart /
Statusmeldung
HW-Version
SW-Version
Press the >>UP<< button to access pages 2 to 5.
METPOINT
SF53
®
FLM, power it up and perform the sensor setup as described in "Sensor Setup" on Page 28.
®
FLM completes an initialisation procedure and then switches to showing the main menu.
®
Modbus ID
Seiten Nr.
CAL
is a calibration indicator:
After 15 months have elapsed, a pending recalibration is
indicated by
CAL
being shown on the display. This indicator
has no effect on measurement data. The measurement signal is
output as before.
The reminder time interval can be adjusted to customer
requirements at the manufacturer's works.