Range of error numbers Standard dialog text
0 ... 299
300 ... 999
1000 ... 1099
FN15: PRINT
Unformatted output of texts or Q parameter values
Setting the data interface: In the menu option PRINT or
PRINT-TEST, you must enter the path for storing the texts
or Q parameters. See "12 MOD Functions, Setting the
Data Interface" .
The function FN15: PRINT transfers Q parameter values and error
messages through the data interface, for example to a printer.
When you save the data in the TNC memory or transfer them to a
PC, the TNC stores the data in the file %FN15RUN.A (output in
program run mode) or in the file %FN15SIM.A (output in test run
mode).
To output dialog texts and error messages with FN15:
PRINT "numerical value"
Numerical values from 0 to 99:
Numerical values exceeding 100: PLC error messages
Example: Output of dialog text 20
67 FN
5: PRINT20
To output dialog texts and error messages with FN 15:
PRINT "Q parameter"
Application example: Recording workpiece measurement.
You can transfer up to six Q parameters and numerical values
simultaneously. The TNC separates them with slashes.
Example: Output of dialog text 1 and numerical value for Q1
70 FN
5: PRINT /Q