Residential Configuration
Rated
Item
Amount
Power(kW)(1)
1
2.4
2
4.8
3
7.2
4
9.6
5
12.0
6
14.4
7
16.8
8
19.2
UP5000
9
21.6
10
24.0
11
26.4
12
28.8
13
31.2
14
33.6
15
36.0
16
38.4
(1) Rated Power is based on ideal operation temperature(10 - 45 ℃ ) , ensuring charging the power will decrease in levels when reaching full capacity.
(2) Min. Back-up time is based on rated power and related condition during beginning of life, in real application please consider the load.
Page 12
Max Power(kW,
Peak Power(kW,
60S)
15S)
4.8
4.3
9.6
8.6
14.4
13.0
19.2
17.3
24.0
21.6
28.8
25.9
33.6
30.2
38.4
34.6
43.2
38.9
48.0
43.2
52.8
47.5
57.6
51.8
62.4
56.2
67.2
60.5
72.0
64.8
76.8
69.1
Nominal
Capacity(kWh)
Capacity(kWh)
4.8
9.6
14.4
19.2
24.0
28.8
33.6
38.4
43.2
48.0
52.8
57.6
62.4
67.2
72.0
76.8
Contact SegenSolar (PTY) Ltd | e: info@segensolar.co.za | t: 08780 20663
Usable
Min. Back-up
time(2)
4.6
9.1
13.7
18.2
22.8
27.4
31.9
36.5
41.0
1.9hrs
45.6
50.2
54.7
59.3
63.8
68.4
73.0

Hide quick links: