Digital Output State After Hot Reset (Jp1); Digital Input Type - Advantech PCI-1758 Series User Manual

Table of Contents

Advertisement

Table 3.1: Board ID Settings (SW1)
15
Default setting = 0
3.3.2

Digital Output State After Hot Reset (JP1)

The default status of the PCI-1758 series cards' digital output after a system power
on is OPEN to protect external devices from damage. JP1 determines whether the
last output value is retained after a hot system reset. Table 3.2 shows the jumper
positions for power on configuration.
Table 3.2: Digital Output State After Hot Reset (JP1)
JP1
3.3.3

Digital Input Type

This jumper is for PCI-1758UDI and PCI-1758UDIO to set digital input type. The type
can be wet contact or dry contact. Table 3.3 shows the jumper positions for digital
input type.
Table 3.3: Digital Input Type
JP3: Digital input channel 0 ~ 15
JP4: Digital input channel 16 ~ 31
JP5: Digital input channel 32 ~ 47
JP6: Digital input channel 48 ~ 63
JP7: Digital input channel 64 ~ 79 (PCI-1758UDI only)
JP8: Digital input channel 80 ~ 95 (PCI-1758UDI only)
JP9: Digital input channel 96 ~ 111 (PCI-1758UDI only)
JP10: Digital input channel 112 ~ 127 (PCI-1758UDI only)
PCI-1758 Series User Manual
OFF
OFF
Digital Output State After Hot Reset
Reset to default (power-on) value
Keep last status
Wet contact
Dry contact
OFF
14
OFF

Advertisement

Table of Contents
loading