a. Only for kitchen tap with flexible hoses:
Connect your kitchen tap hose to one of the two 3/8" male
t-piece connections. Please, ensure proper sealing with the
already existing gasket from your existing kitchen tap hose.
This gasket is already integrated in the hose or a separate
part depending on your kind of kitchen tap hose.
b. Only for kitchen tap with squeeze connections (for kitchen
taps with tubes)
Connect your kitchen tap tube to one of the two 3/8" male
t-piece connections. Please, use the existing squeeze con-
nection nut with sealing components (as used before) and
the tube for the connection of your 3/8" kitchen tap to the
3/8 male t-piece connection.
B a) Put the hose (1) in place
b) Insert the medium-sized (3/8") gaskets into the respective
female threads of the two hose ends.
c) Now connect one end of the hose (1) to the filter head inlet.
This is labelled "IN" (inlet) and marked with an arrow. Make
sure the gasket is seated correctly!
d) Now connect the other end of the hose (1) to your free cold
water supply/installed t-piece and ensure that the gasket is
correctly positioned!
If your cold water supply does not fit the 3/8" connector
on the hose (1), use the supplied adapter if required. Your
mypure P1 Filtration System comes with a 1/2" adapter.
Please go to your nearest supplier for adapters in other
sizes.
C a) Put the hose (2) in place.
b) Connect the small end, with the gasket that has already been
inserted into the hose (2), to the BRITA Dispenser already
installed (see Step 3.3).
D a) Insert the appropriate gasket (3/8") into the 3/8" end of the
hose (2) and connect the 3/8" end of the hose (2) to the outlet
of the filter head, labelled with an "OUT" arrow.
b) Make sure all connections are tightened properly. Avoid over
tightening.
c) Turn on the cold water supply.
The max. tightening torque for the G3/8" connections
may not exceed 14 Nm! Only hose connections with
!
gaskets (5) may be used, because hoses with conical screw
connections damage the connections of the filter head and
invalidate any warranty claims!