Analog Input (AI) Commands (Acknowledged)

ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
1
-
1
ACK
2
-
1
ACK
2
-
1
ACK
2
-
1
ACK
2
-
1
ACK
2
-
1
ACK
2
-
1
ACK,
7
2
1
no
action
ACK
7
3
1
no
action
ACK,
7
7
1
no
action
ACK,
7
8
1
no
action
MG.90.C1.02 - VLT is a registered Danfoss trademark
1-24
1
Byte
Read
Analog Input
1-24
2
Byte
Read
Analog Input
1-24
3
Float
Read
Analog Input
1-24
8
Float
Read
Analog Input
1-24
9
Float
Read
Analog Input
1-24
10
Float
Read
Analog Input
1-24
11
Float
Read
Analog Input
1-24
12
Float
Read
Analog Input
1-24
1
Byte
Write
Analog Input
1-24
8
Float
Write
Analog Input
1-24
9
Float
Write
Analog Input
1-24
10
Float
Write
Analog Input
1-24
11
Float
Write
Analog Input
1-24
12
Float
Write
Analog Input
1-24
-
Float
Override
Analog Input
1-24
-
-
Override
Release
1-24
-
-
Write
Analog Input
Attributes
1-24
-
-
Read Analog
Input
Attributes
VLT
®
2800 Metasys N2
-
Read Object Configuration attribute
associated with each individual point.
-
1) Read Object Status attribute
associated with each individual point.
-
2) Read Analog Input Value attribute
associated with each individual point.
-
Read Low Alarm attribute associated
with each individual point.
-
Read Low Warning attribute associated
with each individual point.
-
Read High Warning attribute associated
with each individual point.
-
Read High Alarm attribute associated
with each individual point.
-
Read Differential attribute associated
with each individual point.
-
Write to Object Configuration attribute
associated with each individual point.
-
Write to Low Alarm Limit attribute
associated with each individual point.
-
Write to Low Warning Limit attribute
associated with each individual point.
-
Write to High Warning Limit attribute
associated with each individual point.
-
Write to High Alarm Limit attribute
associated with each individual point.
-
Write to Differential attribute associated
with each individual point.
-
Analog inputs are "outputs" from the VLT
2800 and should not be written over by
the network controller.
-
Analog inputs are "outputs" from the VLT
2800 and should not be written over by
the network controller.
-
Optional command for slave devices.
Only used for N2 commissioning
purposes.
-
Optional command for slave devices.
Only used for N2 commissioning
purposes. Not to be implemented at this
time.
9