Danfoss VLT 2800 Manual
Hide thumbs Also See for VLT 2800:

Advertisement

Quick Links

DANGER
!
Rotating shafts and electrical equipment
can be hazardous. Therefore, it is strongly
recommended that all electrical work
conform to National Electrical Code
(NEC) and all local regulations.
Installation, start-up and maintenance
should be performed only by qualified
personnel.
Factory recommended procedures, included in this manual,
should be followed. Always disconnect electrical power before
working on the unit.
Although shaft couplings or belt drives are generally not
furnished by the manufacturer, rotating shafts, couplings and
belts must be protected with securely mounted metal guards that
are of sufficient thickness to provide protection against flying
particles such as keys, bolts and coupling parts. Even when the
motor is stopped, it should be considered “alive” as long as its
controller is energized. Automatic circuits may start the motor at
any time. Keep hands away from the output shaft until the motor
has completely stopped and power is disconnected from the
controller.
Motor control equipment and electronic controls are connected
to hazardous line voltages. When servicing drives and
electronic controls, there will be exposed components at or
above line potential. Extreme care should be taken to protect
against shock. Stand on an insulating pad and make it a habit to
use only one hand when checking components. Always work
with another person in case of an emergency. Disconnect
power whenever possible to check controls or to perform
maintenance. Be sure equipment is properly grounded. Wear
safety glasses whenever working on electric control or rotating
equipment.
Touching electrical parts may be fatal – even after equipment
has been disconnected from AC line. To be sure that capacitors
have fully discharged, wait 14 minutes after power has been
MG.90.C1.02 - VLT is a registered Danfoss trademark
VLT
Safety Guidelines
1.
2.
3.
4.
Warnings Against Unintended Start
1.
2.
3.
4.
The Electronic Thermal Relay (ETR) in UL listed VLTs provides
Class 20 motor overload protection in accordance with NEC in
single motor applications, when parameter 117 is set for “ETR
TRIP 1”, “ETR TRIP 2”, “ETR TRIP 3”, or “ETR TRIP 4”, and
parameter 105 is set for rated motor (nameplate) current.
DANGER
!
©Copyright 2001, Danfoss Graham
®
2800 Metasys N2
The drive must be disconnected from the AC line before
any service work is done.
The “Stop/Off” key on the local control panel of the drive
does not disconnect the equipment from the AC line and is
not to be used as a safety switch.
Correct protective grounding of the equipment must be
established. The user must be protected against supply
voltage and the motor must be protected against overload
in accordance with applicable national and local
regulations.
Ground currents are higher than 3 mA.
While the drive is connected to the AC line, the motor can
be brought to a stop by means of external switch closures,
serial bus commands or references. If personal safety
considerations make it necessary to ensure that no
unintended start occurs, these stops are not sufficient.
During programming of parameters, the motor may start.
Be certain that no one is in the area of the motor or driven
equipment when changing parameters.
A motor that has been stopped may start unexpectedly if
faults occur in the electronics of the drive, or if an overload,
a fault in the supply AC line or a fault in the motor
connection or other fault clears.
If the “Local/Hand” key is activated, the motor can only be
brought to a stop by means of the “Stop/Off” key or an
external safety interlock.
NOTE
It is responsibility of user or person
installing drive to provide proper
grounding and branch circuit protection
for incoming power and motor overload
according to National Electrical Code
(NEC) and local codes.

Advertisement

Table of Contents
loading

Summary of Contents for Danfoss VLT 2800

  • Page 1 Touching electrical parts may be fatal – even after equipment has been disconnected from AC line. To be sure that capacitors have fully discharged, wait 14 minutes after power has been ©Copyright 2001, Danfoss Graham MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 3: Table Of Contents

    APPENDIX A: Metasys Point Mapping Tables Analog Inputs (AI) .......................... 18 Binary Inputs (BI) ........................... 19 Analog Outputs (AO) ........................21 Binary Outputs (BO) ........................21 Internal Floating Points (ADF) ......................22 Internal Integers (ADI) ........................23 MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 4: Introduction

    It is assumed that the user has full knowledge of the capabilities and limitation of the controller node in addition to full knowledge of the VLT 2800 drive. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 5: Abbreviations And Definitions

    An N2 master is either a PC with JCI software or a dedicated JCI controller. Not acknowledged N2 Point Address (Each N2 Point Type has a address range from 1 to 255, or 0 to 254.) N2 Point Type Par. Param eter Number MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 6: Network Connection

    (S) at only one point in the system. The Metasys reference wire (REF) may be connected to terminal 70, but this is not necessary. Figure 1. Network Connection MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 7: Error Codes

    ® 2800 Metasys N2 I I I I I Error Codes I I I I I VLT 2800 N2 Startup Error Code 00 is issued after power-up or after a Use the VLT 2800 keypad, mounted either on the time out where all overridden points were released,...
  • Page 8: General Commands (Acknowledged)

    JCI device. ACK, Synch Time No internal clock is available on the basic control card. action ACK, Upload Optional, not support in VLT 2800 N2 action ACK, Upload Optional, not support in VLT 2800 N2 action ACK, Upload...
  • Page 9: Analog Input (Ai) Commands (Acknowledged)

    Only used for N2 commissioning Attributes purposes. action ACK, 1-24 Read Analog Optional command for slave devices. Input Only used for N2 commissioning action Attributes purposes. Not to be implemented at this time. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 10: Analog Input (Ai) Commands (Not Acknowledged)

    Write Analog Write to AI Offset attribute Input associated with each individual point. (JCI use only) Error code 11 is used because attributes are considered as fields/records in the point map database. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 11: Analog Output (Ao) Commands (Acknowledged)

    Not to action be implemented at this time. ACK, Read Analog Optional command for slave Output devices. Only used for N2 Attributes commissioning purposes. Not to action be implemented at this time. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 12: Analog Output (Ao) Commands (Not Acknowledged)

    Float Write Analog Write Accumulator value attribute Output associated with each individual point. (JCI use only) Error code 11 is used because attributes are considered as fields/records in the point map database. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 13: Binary Input (Bi) Commands (Acknowledged)

    Not to action be implemented at this time. ACK, 1-72 Read Binary Optional command for slave Input devices. Only used for N2 Attributes commissioning purposes. Not to action be implemented at this time. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 14: Binary Input (Bi) Commands (Not Acknowledged)

    Integer 32 Write Binary Write Accumulator value Input attribute associated with each individual point.(JCI use only) Error code 11 is used because attributes are considered as fields/records in the point map database. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 15: Binary Output (Bo) Commands (Acknowledged)

    Write Binary Optional command for slave Output devices. Only used for N2 Attributes commissioning purposes. action ACK, Read Binary Optional command for slave Output devices. Only used for N2 Attributes commissioning purposes. action MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 16: Binary Output (Bo) Commands (Not Acknowledged)

    Integer Write Write Interstage off delay attribute Binary associated with each individual point. Output (JCI use only) Error code 11 is used because attributes are considered as fields/records in the point map. MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 17: Internal Integers (Adi) Commands (Acknowledged)

    Write to internal parameter current Internal value (set-up parameters for VLT). Parameter of object type float 1-42 Override Set the current value, the value Release that it was before the 1. Override Command was issued MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 18: Appendix A: Metasys Point Mapping Tables

    Terminal 53 analog Reserved Terminal 60 analog Pulse reference External reference Inverter temperature Hour Operating hours Hour Hours run kWh counter Number of power-ups Number of over temps Number of over volts MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 19: Binary Inputs (Bi)

    Out of frequency range 0=FALSE, 1=TRUE Output current high Feedback low 0=FALSE, 1=TRUE 0=FALSE, 1=TRUE Feedback high Reserved Reserved Live zero error 0=OK, 1=Warning The values in bold are default values. Appendix A MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 20 Switch mode fault 0=OK, 1=Alarm Short circuit Std bus timeout 0=OK, 1=Alarm 0=OK, 1=Alarm Reserved AMT tuning fail 0=OK, 1=Alarm Trip lock 0=Trip, 1=Trip lock The values in bold are default values. Appendix A MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 21: Analog Outputs (Ao)

    0= Not active, 1 = Active 0= Not active, 1 = Active 0= Not active, 1 = Active Relay 01 0= Not active, 1 = Active Reverse The values in bold are default values. Appendix A MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 22: Internal Floating Points (Adf)

    0 to Max. output freq. Reserved Reserved Reserved Reserved Reserved Reserved Reserved Output freq. low limit 0 to Max. freq. Output freq. high limit Min. freq. to Max. freq. range Appendix A MG.90.C1.02 - VLT is a registered Danfoss trademark...
  • Page 23: Internal Integers (Adi)

    18, 19, 27, 29, or 33. Internal Integers (ADI) UNIT Description Range VLT 2800 PNU Active setup 1 to 4 The point is global in all 4 setups Appendix A MG.90.C1.02 - VLT is a registered Danfoss trademark...

Table of Contents