Setting procedure and
checking items
Emission halt input
release
Receiver's control
3
output (OSSD 1,
OSSD 2) OFF
(Emission halt)
Emission halt input
+24V
Receiver's control
output (OSSD 1,
OSSD 2) ON
When light is stably
received
(Approx. 115% or
less)
(Note 1)
4
Emission halt input
+24V
Receiver's control
output (OSSD 1,
OSSD 2) ON
When light is
unstably received
(Approx. 100 to
115% or less)
(Note 1)
Notes: 1) The threshold where the control output (OSSD 1, OSSD 2) changes from OFF to ON is applied as
'100% incident beam intensity'.
2) Since the color of the operation indicator changes according to the ON / OFF state of the control
output (OSSD 1, OSSD 2), the operation indicator is marked as OSSD on the sensor.
3) This is for emission in normal mode. In case of emission in short mode, lights up in orange.
- 68 -
Emitter
© Panasonic Industrial Devices SUNX Co., Ltd. 2013 MJE-SF4A No.0038-55V
Indicators
Receiver
Control output
OSSD 1
OSSD 2