Sensor Installation - Panasonic HL-G2 Series User Manual

Laser displacement sensor
Hide thumbs Also See for HL-G2 Series:
Table of Contents

Advertisement

3.2 Sensor Installation

1.
When installing this product, use M4 captive washer screws (to be prepared separately).
(Tightening torque: 0.8 N∙m or less)
● Carefully handle the sensor so that no force is applied around the connector of the
optional cable. Do not bend the cable close to the connector. Doing so may cause
disconnection.
● Do not bend the optional cable to a radius of 50 mm or less.
● To prevent the sensor from falling due to screw loosening, take preventive measures
such as using captive washer screws depending on the usage environment.
● Install the sensor so that the beam emitting part and beam receiving part surfaces are set
in parallel with the measurement object.
WUME-HLG2AN-2

3.2 Sensor Installation

3-3

Advertisement

Table of Contents
loading

Table of Contents