5.9 Output Commands (Setting/Measurement/Data Output)/5.10 Output Commands (RS-485 Dedicated Commands)
p2 Path name (up to 150 characters)
Setting memory:
/SETMEMORY/file name
Internal memory:
/INTERNALMEMORY/file name
CF memory card:
/CFCARD/file name
SD memory card:
/SDCARD/file name
p3 Maximum number of output file lists
1 to 100
If omitted, all the file lists in the specified
directory are output.
Example
• Output the list of all files on the CF memory
card.
ME DIR,/CFCARD/
• Output 10 files of the file list on the CF
memory card.
ME DIR,/CFCARD/,10
• Output the list of all files in the DATA0
directory on the CF memory card.
ME DIR,/CFCARD/DATA0/*.*
• Output the list of all display data files in the
DATA0 directory of the CF memory card.
ME DIR,/CFCARD/DATA0/*.BMP
• Output the data in the file 72615100.DLO in
the DATA0 directory on the CF memory card.
ME GET,/CFCARD/DATA0/72615100.DLO
Description • This command is valid for the specified save
destination and load destination medium.
• Parameter p2 is valid when p1 is set to DIR,
GET, or DEL.
• Parameter p3 is valid when p1 is set to DIR.
• This command can be used to output data
over the communication interface (Ethernet or
serial) that was selected with the XO
command.
• If an error occurs during data transmission,
(p1=) RESEND can be used to retransmit the
data.
IM XL100C-E
5.10 Output Commands (RS-485
Dedicated Commands)
ESC O Opens the device
The ASCII code of ESC is 1BH.
See appendix 1, "ASCII Character Codes."
ESC O p1<terminator>
Syntax
p1 Device address
Example
Open the device at address 01, and enable all
commands.
ESC O 01
Description • Specifies the address of the device with which
to communicate.
• Only one device can be opened at any given
time.
• When a device is opened with the ESC O
command, another device that is currently
open is automatically closed.
• When this command is received correctly, the
XL100 transmits the data "ESC O
• Normally, either CR+LF or LF can be used as
a terminator for communication commands.
However, the terminator for this command
must be set to CR+LF.
ESC C
Closes the device
The ASCII code of ESC is 1BH.
See appendix 1, "ASCII Character Codes."
ESC C p1<terminator>
Syntax
p1 Device address
Example
Close the device whose address is 01.
ESC C 01
Description • Clears the current connection with the device.
• When this command is received correctly, the
XL100 transmits the data "ESC C
• Normally, either CR+LF or LF can be used as
a terminator for communication commands.
However, the terminator for this command
must be set to CR+LF.
01 to 99
".