Calculating current limitations

The ECdry floor heating system should be
connected in accordance with national stan-
dards and wiring rules.
Maximum current per ECdry system is 10
Ampere.
Maximum heated surface per ECdry Touch Kit (10 A limit per system)
Product
ECdry 55
ECdry 100
For ECdry 55 (Mains voltage 230 Volt and 50 Hz)
Floor area
1 m²
2 m²
3 m²
4 m²
5 m²
For ECdry 100
Floor area
1 m²
2 m²
3 m²
4 m²
5 m²
14 | Danfoss © | 2020.07
Danfoss ECdry Touch Kit
Heated surface
0,4 m²
1,4 m²
2,4 m²
3,4 m²
4,4 m²
Heated surface
0,4 m²
1,4 m²
2,4 m²
3,4 m²
4,4 m²
In the following tables you will find maxi-
mum heated surface per ECdry Touch Kit
and an overview of the total power output
of the systems.
Max heated surface
42 m²
23 m²
Total power output
22 Watt
77 Watt
132 Watt
187 Watt
242 Watt
Total power output
40 Watt
140 Watt
240 Watt
340 Watt
440 Watt
Ampere
0,10 A
0,33 A
0,57 A
0,81 A
1,05 A
Ampere
0,17 A
0,61 A
1,04 A
1,48 A
1,91 A