4.6
Standard Set-up Procedures

Drop Manhole

The trivet pole or the complete trivet assembly is designed to attach directly
to a drop manhole t-bar assembly using a 5/8"-11 mount.
Ensure that the T-bar is level and perpendicular to the pipe. Tighten the wing nut
on the T-bar to secure it in the manhole. Move the Piper up or down on the
adjustable pole until the beam is approximately at the required elevation.
Set the line. Adjust the beam so that it is in line with the next manhole.
Set the grade. Enter the required grade
for the pipe to be laid in the display of the
Piper.
Set the elevation. Lower the pre-
assembled Drop Manhole Assembly and
Piper into the manhole until the T-bar is
approximately 150 to 300 mm (6 to 12
inches) above or below the pipe.