Display
Symptom
Target, Question
Mark, and Sun Icon
Beam is not hitting
the center of the
target.
The Remote
Control is not func-
tioning
Troubleshooting
Possible Causes and Solutions
The Target, Question Mark and Sun Icon indicates that the Piper is
in too bright of light conditions for the Alignmaster fucntion to
find the target. Try shading to reduce the affects of the sun.
This symptom may be caused by the following possible causes:
The Piper of Target has not been set up properly or has been
moved. Check and try again.
The pipe has not beed correctly adjusted to grade. Check and
try again.
The pipe or water in the pipe is reflecting the beam. If
possible, drain the pipe and try again.
Conditions inside the pipe are refracting the beam. See
section on refraction for remedy.
The Piper is out of adjustment. Perform accuracy check.
This symptom may be caused by the following possible causes:
Line movement may be locked.
The remote is too far from the Piper to activate the function
desired. Move closer and try again.
The Remote's battery may be low. Replace the battery and try
again.