Leica PIPER 100 User Manual page 65

Hide thumbs Also See for PIPER 100:
Table of Contents

Advertisement

a
b
c
d
Accuracy Adjustment
Access to the Adjustment Screen
If power is ON, turn it OFF.
Press and hold the DOWN and RIGHT arrow buttons, then press the POWER
button (a) to turn the unit on and enter the adjustment mode / screen.
The adjustment screen will appear as illustrated here (b).
Adjusting Level Accuracy
When the accuracy of the Piper has been checked, and the amount of error is
known, the beam position is adjusted using the UP and DOWN arrow buttons (c)
to increment the counter and move the beam to the desired position.
Each count represents approximately two arc seconds. Therefore, five counts of
the counter is approximately equal to 1.6 mm at 30 meters (1/16 inch at 100
feet).
The Piper icon will blink to indicate that the unit has not reached the level posi-
tion.
The LEFT or RIGHT arrow buttons (d) may be used to move the line during this
procedure.
65

Advertisement

Table of Contents
loading

This manual is also suitable for:

Piper 200

Table of Contents