IBC Sl Series Installation & Operating Manual page 90

Residential condensing boiler
Hide thumbs Also See for Sl Series:
Table of Contents

Advertisement

Warning
Before replacing the condensate trap, turn off the power to the boiler and allow to cool
down.
1.
To remove the trap pan, undo the
two wing nuts. Note the orientation of
the hose.
3.
Unscrew the condensate union cap at
the base of the trap, empty the water and
flush the trap with water.
Section: Service and maintenance
2.
Loosen the upper union nut,
and slide the condensate trap
off the boiler drain outlet.
4.
Fill the condensate trap to the top
with water and replace the union cap
and gasket
86

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sl 10-85 g3Sl 14-115 g3Sl 20-160 g3Sl 30-199 g3

Table of Contents