3.1.4.1.1 Multiplexed mode port function register setting
Using Multiplexed mode lower pin count is required because of Multiplexed address-
data bus usage. In Multiplexed mode ASX signal is required. Find the different port
function setting below:
;====================================================
; 4.9.10 Select External bus mode (Address lines)
;====================================================
#set
PFUNC6
B'00000000
;
||||||||__ A8 /
;
|||||||___ A9 /
;
||||||____ A10 /
;
|||||_____ A11 /
;
||||______ A12 /
;
|||_______ A13 /
;
||________ A14 /
;
|_________ A15 /
#set
PFUNC7
B'00000000
;
||||||||__ A0 /
;
|||||||___ A1 /
;
||||||____ A2 /
;
|||||_____ A3 /
;
||||______ A4 /
;
|||_______ A5 /
;
||________ A6 /
;
|_________ A7 /
#set
PFUNC10
B'00011010
;
|||||||__ (SYSCLK or !SYSCLK) / P10_0
;
||||||___
;
|||||____ BAAX / P10_2
;
||||_____
;
|||______
;
||_______ (MCLKI or !MCLKI) / P10_5
;
|________ MCLKE / P10_6
© Fujitsu Microelectronics Europe GmbH
Interfacing MB91460 TO MB88121
Chapter 3 Software
;select address lines
P06_0
P06_1
P06_2
P06_3
P06_4
P06_5
P06_6
P06_7
;select address lines
P07_0
P07_1
P07_2
P07_3
P07_4
P07_5
P07_6
P07_7
;select control signals
ASX
/ P10_1
WEX
/ P10_3
(MCLKO or !MCLKO)
- 33 -
/ P10_4
MCU-AN-300016-E-V10