  • Page 1 Fujitsu Microelectronics Europe MCU-AN-300000-E-V11 Application Note F²MC-8L FAMILY 8-BIT MICROCONTROLLER MB89201 SERIES GETTING STARTED APPLICATION NOTE...
  • Page 2: Revision History

    MB89201 Series – Getting Started Revision History Revision History Date Issue 2005-01-10 V1.0 Markus Vogel - First draft 2005-02-03 V1.1 Markus Vogel - Corrected typos This document contains 15 pages. MCU-AN-300000-E-V11 - 2 - © Fujitsu Microelectronics Europe GmbH...
  • Page 3: Warranty And Disclaimer

    Product or parts thereof, if the Product is returned to Fujitsu Microelectronics Europe GmbH in original packing and without further defects resulting from the customer´s use or the transport.
  • Page 4: Table Of Contents

    3 EMULATION SYSTEM SETUP..................9 4 SETTING UP THE EMULATION SOFTWARE............... 11 Software Versions ....................11 Set up a new project....................11 Setup File for the emulator ..................13 5 STANDALONE EPROM MODE ..................15 MCU-AN-300000-E-V11 - 4 - © Fujitsu Microelectronics Europe GmbH...
  • Page 5: Introduction

    MB89201 Series – Getting Started Chapter 1 Introduction 1 Introduction This application note describes how to start development with the Fujitsu F MC-8L Family MB89201 Series. The first chapter explains the tools like the F MC-8L emulator Compact-ICE MSE1001C and the evaluation board FMPDC-MB89V201-ADPB with mounted evaluation chip MB89V201.
  • Page 6: Hardware Tools

    Also supply 5 volts DC to the connection terminal on the backside of the Compact-ICE. Warning: Take care that the supply voltage is fixed to 5 volts DC. Otherwise it may damage Compact-ICE or other connected tools! MCU-AN-300000-E-V11 - 6 - © Fujitsu Microelectronics Europe GmbH...
  • Page 7: Evaluation Board

    Before starting there has to be mounted a crystal oscillator (1 MHz up to 12,5 MHz) and two capacitors (e.g. 22 nF) in the main clock socket. Crystal oscillator MCLK © Fujitsu Microelectronics Europe GmbH - 7 - MCU-AN-300000-E-V11...
  • Page 8: Emulation Probe

    To connect the evaluation board to the user target system the emulation probe with SDIP socket and flat cable can be used. On emulation probe and evaluation board there are prepared 40-pin connectors (CN2 on evaluation board) for this issue. MCU-AN-300000-E-V11 - 8 - © Fujitsu Microelectronics Europe GmbH...
  • Page 9: Emulation System Setup

    3. If you want to use the emulation probe connect the flat cable to CN2 on the evaluation board before mounting it on the Compact-ICE. Flat cable to CN2: emulation probe Connector for the emulation probe © Fujitsu Microelectronics Europe GmbH - 9 - MCU-AN-300000-E-V11...
  • Page 10 9. To turn off power, first power of the evaluation board and after that the Compact-ICE. Warning: Please hold strictly to the above given power on/off sequence to avoid damage off the evaluation board and the Compact-ICE! MCU-AN-300000-E-V11 - 10 - © Fujitsu Microelectronics Europe GmbH...
  • Page 11: Setting Up The Emulation Software

    There are also several example projects. The ‘Template’ project includes the startup code, header files and vector table for the MB89201 series. Copy the folder ‘Template’ within the example-folder and rename ‘Copy of Template’ into ‘my_application’. © Fujitsu Microelectronics Europe GmbH - 11 - MCU-AN-300000-E-V11...
  • Page 12 ‘template.wsp‘ into ‘my_application.wsp’ Edit ’my_application.prj’ and rename the symbol ‘template’ into ‘my_application’. Edit ‘my_application.wsp’ and rename the symbol ‘template’ into ‘my_application’. my_application.wsp my_application.prj Start Softune Workbench and open your project ‘my_application.wsp’: MCU-AN-300000-E-V11 - 12 - © Fujitsu Microelectronics Europe GmbH...
  • Page 13: Setup File For The Emulator

    To enter emulation double-click on Emulate.sup in folder Debug. Debug mode is entered. If this setting does not exist yet in your project, start setup wizard by right-clicking on ‘Debug’ and choose ‘Add Setup’ -> ‘New…’. © Fujitsu Microelectronics Europe GmbH - 13 - MCU-AN-300000-E-V11...
  • Page 14 Now follow the steps in the next windows. Choose ‘Emulator Debugger’ and ‘Compact ICE’. Choose your right COM-port and set the baud rate. Select ‘Auto load when starting debug’ option. After all settings are done click ‘Finish’. MCU-AN-300000-E-V11 - 14 - © Fujitsu Microelectronics Europe GmbH...
  • Page 15: Standalone Eprom Mode

    Mount the EPROM on the socket on the evaluation board. Remove jumper plug J1 and set SW1-3 to ON. Additionally set jumper plug J2 and SW1-4 to ON for use off the on-board reset button. Pin 1 © Fujitsu Microelectronics Europe GmbH - 15 - MCU-AN-300000-E-V11...