6 – Interfaces

6.3.2 Power Interface [A6705 only]

The camera is designed for +24VDC power. An AC/DC power supply is not provided with the
camera. The power connector is an industrial standard M8-3 type. The power input pin out is shown
in Figure 6-.
Figure 5-1: A6705 Power Input Pinouts
When using your own DC power supply, you should take note of the following information:
Input voltage: 24 VDC nominal (20-28V acceptable)
Current draw: 1.4 amps nominal steady state, 2.6 amps peak (during cool down)
A6705 power dissipation is <50 Watts steady state at nominal ambient temperature.
Mating Connector: Digikey PN 277-4338-ND, Phoenix Contact PN 1681172

6.4 Lens Interfaces

6.4.1

C-Mount (A626x only)

The A6260 and A6261 supports a standard C-mount interface. The camera ships with the C-mount
interface installed. The A6260sc has the FPA (detector) position set for the standard C-mount back
working distance of 17.526 mm (0.6900 inches).
Figure 6-8: Removable lens mount