5.4.2.3 Frame Sync Starts Integration (FSSI)

Upon frame sync, the camera immediately integrates followed by data read out. Based on integration
time, frame size, and frame rate, the camera will automatically choose ITR or IWR mode.
NOTE: When using an external frame sync and superframing, the external frame sync should be set
to comply with ITR frame rate limits. If the external sync rate is too fast, the camera will ignore syncs
that come before the camera is ready
Frame Sync
Preset 0
Integration
Preset 0
Data
Frame Sync
Frame 1 Integration

5.4.2.4 Frame Sync Starts Readout (FSSR)

Upon frame sync, the camera immediately transmits the data from the previous frame. The integration
period is then placed to meet ROIC requirements. This mode always operates in IWR mode. This
mode can be used with either internal or external frame sync at full frame rates.
Frame Sync
Frame 1 Integration
A6000 and A8500 Series User's Manual
Frame Sync
Preset 1
Integration
Preset 1
Data
Frame Sync Starts Integration, ITR
Frame Sync
Frame 2 Integration
Frame 1 Data
Frame Sync Starts Integration, IWR
Frame Sync
Frame 2 Integration
Frame 1 Data
Frame Sync Starts Readout
Frame Sync
Preset 2
Integration
Frame Sync
Frame 3 Integration
Frame 2 Data
Frame Sync
Frame 3 Integration
Frame 2 Data
5 –Camera Controller
Frame Sync
Preset 3
Integration
Preset 2
Data
Frame Sync
Frame 4 Integration
Frame 3 Data
Frame Sync
Frame 4 Integration
Frame 3 Data
Preset 3